5-15
Figure 5
-
6 Troubleshooting Radio RCV Alarms (Sheet 3 of 5)
A
STATUS
Receiver Fault
Receiver On Line
Channel Fail
Radio Dade
Eye Closure
Low RSL
Path Distortion
Radio Frame Loss
RECEIVER
MDR-1083
05/20/05
Loss of radio frame from RCVR in I/O Interface RCVR circuits. Before
starting, check USI for receiver
Channel Fail
alarms and
Common
Command Path
alarm. If there is a
Channel Fail
alarm, troubleshoot and
clear that alarm first. If there is a
Command Path
alarm, troubleshoot and
clear that alarm second.
1.
Verify farend radio configuration. Is farend radio hot-standby?
Yes, go to 2.
No, go to 4.
2.
Check for Radio Frame Loss alarms on both A and B.
Are there Radio Frame Loss radio frame loss alarms on both A
and
B?
Yes, go to 3.
No, only A or B has a frame loss alarm, go to 4.
3.
Switch farend XMTRs. Do alarms clear?
Yes, replace farend off-line XMTR.
No, replace local I/O Interface on alarmed side. Do alarms clear?
Yes, stop. Procedure is complete.
No, replace local RCVR on alarmed side.
4.
Replace local I/O Interface on alarmed side. Do alarms clear?
Yes, stop. Procedure is complete.
No, replace local RCVR on alarmed side.
Note
Al
wa
ys troubleshoot
a
nd cle
a
r the most severe
a
l
a
rm first.
Channel Fail
is the most severe, follo
w
ed by R
a
dio Fr
a
me
Loss
a
nd Eye Closure.