5-57
Figure 5
-
21 XMTR Output Level Calibration (Sheet 2 of 5)
PWR MON
XMT PWR
ALM
ON LINE
I CARR NULL
XMT LVL
ADJ
FREQ CONT
Q CARR NULL
TRANSMITTER
TRANSMIT POWER CALIBRATION
Communicating*
ELMC Address:
Description:
MDR-8000
RACK6
12:17:01 PM
10-May-99
CLICK CALIBRATE A OR B SIDE
Carrier Null A
Carrier Null B
Calibrate B-side
Set your Tx Level to 10 dB below nominal
HIGH power using the (XMT LVL ADJ)
potentiometer on your TRANSMITTER
module. After this is done, click Next.
Set your Tx Level to nominal HIGH power
using the (XMT LVL ADJ) potentiometer on
your TRANSMITTER module. After this is done,
click NEXT.
Calibrate A Side
MDR-1060
09/08/05
Abort
Next
Abort
Next
Back
Example:
Expected output level at top of stack = 14 dBm.
Label on diplexer filter/XMT filter shows insertion loss is 2dB.
Nominal high power out of XMTR = 16 dBm
(14 dBm + 2 dBm = 16 dBm).
Set nominal low power level for 6 dBm
(10 dB down from 16 dBm).
Determine XMTR nominal
high and low output level:
c
XMTR nominal high output level
= level at top of stack + insertion
loss of diplexer filter/XMT filter
(marked on label on filter.
XMTR nominal low output level
= XMTR nominal high output
level – 10 dB.
Proceed to
Sheet 3
d
e
f
g
h
i
Summary of Contents for MDR-8000
Page 2: ......
Page 113: ...5 55...