4-10
Screen shown is for DS1 Radio. E1, DS
3
, OC
3
/STM-1, and ETH radio
configuration provisioning is similar. Changes to provisioning do not
have to be made in any particular order.
Figure 4
-
5 DS1/E1, DS3, OC3/STM-1, ETH Radio Configuration Provisioning (Sheet 2 of 2)
Note
ATPC Enabled
A&B PA Present
RADIO CONFIG:
HS Tx/HS Rx
TERMINAL
6-8 GHz
SYSTEM ALARM
Visual/Audible
RELAYS ON/NO
Station Alarm 13-16
RSL Alarm Enable
RSL-SW Disable
BER Disable
RCV SWITCHING:
RADIO TYPE:
MDR-8000 DS1
16 LINES
128 TCM
OPTIONS:
Stat/Prov/WaySide
Option Key:
SYSTEM ID:
TEST1
Disable
RADIO LINK ID:
ELMC:
Relay Card Present
SELECT
ATPC
OR
ATPC T/O
ENABLE AUTOMATIC XMT POWER CONTROL (ATPC) FUNCTION. WHEN PROVISIONED
ATPC
OR
ATPC T/0
, ONE RCVR OUT-OF-LOCK CAUSES HIGH POWER ATPC FOR 10 SECONDS EVERY ONE MINUTE.
IF BOTH RCVRS ARE OUT-OF-LOCK, ATPC GOES TO HIGH POWER AND STAYS AT HIGH POWER UNTIL ONE RCVR
(REVERTS TO ONE RCVR OUT-OF-LOCK MODE) OR BOTH RCVRS LOCK. WHEN PROVISIONED
ATPC T/O
(TIMEOUT),
IF CMD PATH IS LOST, ATPC GOES TO HIGH POWER FOR FIVE MINUTES THEN GOES TO LOW POWER. THEN, EVERY
HOUR, ATPC GOES HIGH FOR 10 SECONDS AND THEN GOES TO LOW POWER. THIS CONTINUES UNTIL THE CMD
PATH IS RESTORED. SELECT
DISABLE
TO DISABLE ATPC FUNCTION.
NOTES
1. ATPC T/O IS A CMD PATH FUNCTION PERFORMED AT XMTR.
2. ATPC TRACKS RCVR WITH HIGHEST LEVEL.
3. LOW POWER ATPC IS 10dB DOWN FROM HIGH POWER.
MDR-1031
12/06/07
SELECT
RSL Alarm Enable
TO ENABLE ALARM ON USI
ALARM AND STATUS SCREEN WHEN RSL DROPS
BELOW THRESHOLD. SELECT
RSL Alarm Disable
TO
INHIBIT ALARM.
SELECT
Relay Card Present
IF SHELF IS EQUIPPED WITH
A RELAY INTFC MODULE. SELECT
Relay Card Not Present
IF SHELF IS NOT EQUIPPED WITH A RELAY INTFC CARD.