5-5
5.5
PERSONAL COMPUTER (PC)/LAPTOP
The PC is an on-line maintenance and troubleshooting tool. Refer to the General Section
for PC guidelines. See Figure 5
2. Connect the RS-232 Interface cable between USI con-
nector on controller and the PC.
Communications Ana-
lyzer w/DS1 Package
Acterna TB 2310-P4
D1 Data Rate
DS1 Modulation
Scheme
1.544 Mb/s,
B8ZS or AMI
Over-The-Hop DS1 BER Threshold Test
Communications Ana-
lyzer w/DS3 Package
Acterna TB 2310-P5
DS3 Data Rate
DS3 Modulation
Scheme
44.736 Mb/s,
64 QAM
Over-The-Hop DS3 BER Threshold Test
Communications Ana-
lyzer w/OC3 Package
Acterna TB 2310-P2
155.52 Mb/s
Over-The-Hop OC3/STM-1 BER Threshold
Test
Flexible RF Test Cable, 6
Ft.
Tyco Electronics
1049982-5
Spectrum Analyzer
Optical Power Meter
RIFOCS 555B with SC
and FC SOC
Power
Wavelength
-8 to -28 dBM,
1310/1550 nm
Over-The-Hop Optical Power Test
Oscilloscope, Tektronix
TDS3052B
DS3 Radio DADE
DS3 Line DADE
Spectrum Analyzer, Agi-
lent E4408B
1.7 to 11.7 GHz
, In-Service XMTR Carrier Null
Adjustment Using Spectrum Analyzer
Variable Attenuator,
Narda 791
1.7 to 11.7 GHz, 0 to
37.5 dB
Over-The-Hop DS1 BER Threshold Test
,
Over-The-Hop E1 BER Threshold Test,
Over-The-Hop DS3 BER Threshold Test,
Over-The-Hop OC3/STM-1 BER Threshold
Test, OC3/STM-1/ETH I/O Interface
Removal and Replacement,
Over-The-Hop OC3/STM-1 Fade Margin
Test (to the 10-6/10-3 BER Level)
Table 5
-
2 Optional Test Equipment (Cont.)
Test Equipment/Function
Essential Characteristics
Used On
Summary of Contents for MDR-8000