7705 SAR-A Components
42
7705 SAR-A Chassis Installation Guide
T1/E1 and Ethernet Ports
One variant of the 7705 SAR-A chassis is equipped with T1/E1 ports; both variants of the
chassis are equipped with Ethernet ports.
identifies the T1/E1 and Ethernet
interface ports. These ports provide access for a wide variety of interface speeds and types,
including T1/E1 with TDM-based services (SAToP, CESoPSN, and CESoETH), PPP/
MLPPP in access or network mode, and Ethernet (1000Base-T, 100Base-T, 10Base-T, and
optical).
The eight T1/E1 ports use RJ-45 connectors. All eight ports must be configured as either T1
or E1; a mix of T1 and E1 ports is not supported. The T1/E1 ports are on-premises,
intra-building SELV ports and require a CSU for off-premises connections. An adapter cable
is available that converts RJ-45 connectors to BNC connectors for E1 ports. These ports must
be configured for 75
Ω
impedance.
Of the 12 Ethernet ports, ports 1 to 4 are exclusive-OR (XOR) ports that can be configured
as either 10/100/1000 Base-T electrical RJ-45 ports (ports 1A to 4A) or as 100/1000 SFP
ports (ports 1B to 4B). The interface type can be configured on each port independently; the
default is RJ-45. Ports 5 to 8 are also Gigabit Ethernet ports and use 100/1000 SFPs. The SFPs
are hot-swappable and field-replaceable by qualified personnel. Ports 9 to 12 are Fast
Ethernet ports and use an RJ-45 connector.
When making connections to the T1/E1 ports, CAT5e shielded cables must be used to
maintain EMC compliance. When making connections to the Ethernet ports, CAT5 shielded
cable must be used for Fast Ethernet ports and CAT5e shielded cable must be used for Gigabit
Ethernet ports.
Figure 10: T1/E1 and Ethernet Ports
Power Supply Inputs
The 7705 SAR-A supports a –48/–60 VDC power supply through a wire-to-board, modular
pluggable terminal block (with four terminals) attached to the front of the chassis. The
terminals provide access for two independent power feeds, allowing power redundancy for
the system.
7705 SAR-A
Mgmt
ToD Out
Lnk
Act
Sync
In
+Batt A -Batt A +Batt B -Batt B
Console
8
12
11
10
9
7
6
5
4B
3B
2B
1B
1A
Status
2A
3A
4A
Act
Lnk
Act
Lnk
Act
Lnk
Act
Lnk
Stat
Stat
Stat
Stat
2
4
6
8
1
3
5
7
Lnk
Act Lnk
Act Lnk
Act Lnk
Act
Stat
Stat
Stat
Stat
T1/E1
Ethernet
-48 VDC
23312
T1/E1 ports
Ethernet ports
Summary of Contents for 7705 SAR-A
Page 23: ...Mandatory Regulations 7705 SAR A Chassis Installation Guide 23 Figure 3 Earth ground 9718 ...
Page 66: ...Installation Site Assessment 66 7705 SAR A Chassis Installation Guide ...
Page 76: ...Chassis Ground Wiring 76 7705 SAR A Chassis Installation Guide ...
Page 82: ...Wiring and Connecting DC Power 82 7705 SAR A Chassis Installation Guide ...
Page 132: ...7705 SAR A Ports 132 7705 SAR A Chassis Installation Guide ...
Page 154: ... 2015 Alcatel Lucent All rights reserved 3HE 10141 AAAB TQZZA Edition 01 ...