Wiring and Connecting the 100W High Voltage Power Supply to the 7705 SAR-A
90
7705 SAR-A Chassis Installation Guide
Figure 19: 100W High Voltage Power Supply
For redundant power configurations, you must use two power feeds (one for each power
connector on the 7705 SAR-A).
shows the 100W High Voltage Power Supply wired to the 7705 SAR-A;
identifies the key items in the figure.
Figure 20: Wiring the 100W High Voltage Power Supply
23958
DC Output
Single Feed
High Voltage
AC or DC Input
(IEC320-C14
Connector)
100W
High-Voltage
Power
Supply
Mgmt
ToD Out
Lnk Act
Sync
In
+Batt A -Batt A +Batt B -Batt B
Console
-48 VDC
24036
1
1
2
3
2
3