Configuring Slot, IOM, and MDA Parameters
Page 72
7450 ESS-1
Configuring Slot, IOM, and MDA Parameters
After the 7450 ESS-1 is initialized, the MDA and port parameters can be configured. Even though
the IOM is an integral part of the unit, the slot and card type must be manually specified. The
MDA slot and MDA type must be configured in order to configure ports. Ports cannot be
configured until the MDA is configured.
Configure components in the following order:
1. Card slot number
2. Card type
3. MDA slot number
4. MDA type
5. Ports
Card and Card-Type Commands
NOTE
: When configuring the chassis slot (Step 1), the slot number value is always 1 for ESS-1
models.
In the
config>card
context, use the following CLI commands and syntax examples to
provision the chassis slot and IOM:
Command
Example
Step 1
card
slot-number
card 1
Step 2
card-type
card-type
card-type iom-20g
Step 3
no shutdown
no shutdown