TABLE 3. TROUBLESHOOTING AND GENERATOR SET FAULTS
Fault-Problem
Possible reasons
Remedies
Excessive heat lamp is
turned on.
Sea water flow is stopped.
Sea water inlet is closed
Open the sea water intake tap.
Sea water filter system is clogged
Clean the filter system, and
remove the blockage. Always fill
the filter with water before
operating
System pipes or hoses that shall
be operating may be twisted,
punched or leaking from
connection points
Check the connection points to
repair properly and remove the
leaks
Sea Water Pump Internal Gear is
faulty
Replace the internal gear with a
new one.
There may be a blockage in the
installation connection points on
the body of the sea vessel
Check for any blockage. Clean
when required.
Charging Fault lamp is
turned on. Batteries are not
charged adequately
Inadequate battery charge, loose
contact in battery cables and
connection points
Clean the terminals. Check
battery charge and cables.
Tighten connections.
V-belt driving the battery charging
alternator is slackened
Adjust the V-belt slackness
properly, adjust the belt sag to 6-
8mm.
Interference with battery supplied
devices may reduce the desired
effect of the charge
Perform necessary
measurements. Disable the
device when required.
Starting lamp is turned on.
Engine cannot be started
due to the incapability of the
starter
Alternator takes too much energy
from the engine
Turn the circuit breaking fuse to
OFF position
Inadequate battery charge, loose
contact in battery cables and
connection points
Clean the terminals. Check
battery charge and cables.
Tighten connections.
Starting lamp is turned on.
High battery voltage
Connection method to battery
voltage is wrong
Check the connections according
to suitable voltage in the engine.
External battery charging unit is
running
Check the charge of back-up
batteries while charging with an
external device
Speed lamp is turned on.
Generator is operating, it is
not possible to take AC
power from generator (No
voltage generation)
Circuit breaking fuse operating
position is not proper.
Bring the circuit breaking fuse to
ON position
Circuit breaking fuse is faulty.
Replace with new the circuit
breaking fuse
Alternator is faulty
Report authorized service
6
–3
Summary of Contents for MG 309
Page 4: ......