background image

Instructions for installation and operation  -  English 

 

Installation & Use Pares - Marami - Code 10013216 - Edition 2 - 10/2011 – Page 6 

PRE-WIRING OF ELECTRICAL CONNECTIONS 
 
The  electrical  installation  for  the  spa  is  the  customer’s  responsibility.  Under  no  circumstances  are  our  teams 
authorised to carry out work on the customer’s electrical installation. We recommend you call upon the services of a 
certified electrician to ensure compliance of your installation.

 

The installer should refer to standards.

 

 
See also the following documents: 

-

Product technical sheet 

-

Electrical system, safety distances and danger zones for SPA pools with hydromassage 

 

It is the installer’s responsibility to choose the materials according to the planned use, to make sure the works are carried 
out properly, to check the state of the installation to which the appliance is connected, and also to ensure its compliance 
with  the  safety  standards  to  be  applied  during  its  use  and  during  the  maintenance  operations,  making  sure  that  the 
installation can be checked easily. 
 
The  power  supply  installation  must  comply  with  the  provisions  of  the  national  legislation.  The  spa  must  be  permanently 
connected,  without  any  intermediate  connections,  to  the  electric  power  supply  network  and  to  the  protection  circuit 
(grounding). 
 
The spa must be fed without fail through a differential circuit-breaker with a release threshold of 30mA. For the grounding 
connection  provided  for  by  the  directives  in  force,  the  installer  must  use  the  terminal  provided  for  this  purpose  on  the 
electrical box. More specifically, it is necessary to guarantee the equipotentiality of all the metal masses located close to the 
spa. 
 
The connection to the mains must include the grounding connection and be: 

-

of the fixed type 

-

sized for maximum consumption (as shown on the table of the electrical characteristics).  

-

with a level of resistance to liquid penetration (IPX5) in accordance with standards. 

 
 

This  appliance  is  intended  for  home  use.  In  the  event  of  public  use,  guarantee,  in  addition  to  the  technical  and 
safety provisions stipulated by our factory, total compliance with the standards of specific laws for the circuit, safety 
and treatment of the water in force in the country where the spa is to be installed. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for Marami

Page 1: ...Manual de uso Gebruikershandleiding Priro nik za uporabo Priru nik za upotrebu Manuale installazione Installation manual Installationshandbuch Notice d installation Manual para la instalaci n Manual d...

Page 2: ...al treatment of the water 16 4 Use of the spa 16 4 1 Presentation of PARES 16 4 2 Presentation of MARAMI 17 4 3 PARES 18 4 4 MARAMI 18 4 5 Operation of the sand filter Marami with SpaPack only 19 4 6...

Page 3: ...ded installation conditions in the installation manual and make sure they are properly complied with Our factory always endeavours to improve the performances of its spas For this reason it is possibl...

Page 4: ...health In the event of use with young children or elderly people it is advisable to reduce the water temperature WARNING For use by a pregnant woman we recommend having a maximum temperature of 38 C I...

Page 5: ...every two months or more often if necessary In order to obtain the detailed instructions for the cleaning and refitting of the cartridge For complete description refer to chapter 5 1 WARNING Change th...

Page 6: ...STALLATION Make sure that only the base of the spa is embedded and that the side panels remain clear For this type of installation we recommend providing a clearance of approximately 40cm and installi...

Page 7: ...e checked easily The power supply installation must comply with the provisions of the national legislation The spa must be permanently connected without any intermediate connections to the electric po...

Page 8: ...requires the prior consent of the manufacturer Original replacement manufacturer of the pump assumes no liability for the damage and injuries caused by unauthorized replacement parts and accessories W...

Page 9: ...there is no voltage in the circuits including the auxiliary circuits and the supplementary services 4 Wait until the rotor stops completely The above list should be considered indicative and not bind...

Page 10: ...Installation Use Pares Marami Code 10013216 Edition 2 10 2011 Page 9 HYDRAULIC CONNECTIONS CIRCUIT PUMP 1 one speed pump CIRCUIT PUMP 2 two speed pump out 3 in 3 Pump 1 speed out 2 in 2 Pump 2 speeds...

Page 11: ...Instructions for installation and operation English Installation Use Pares Marami Code 10013216 Edition 2 10 2011 Page 10 ELECTRIC CONNECTIONS Circulation Pumb Pump two speeds Pump one speed...

Page 12: ...e Voltage 400 Vac Number of wires 5 Frequency 50 Hz Current consumed see attached table See also the document Electrical system safety distances and danger zones for SPA pools with hydromassage Electr...

Page 13: ...Choose the entry point of the cable on the most suitable side and drill a cable passage of a corresponding diameter either in the base or in the surrounding panel Put in the power supply cable of 230...

Page 14: ...er back on the electrical box 3 2 Filling the spa Only fill the spa at its final location Open all slide valves by lifting the handles and locked it by sliding the locking clips on the axes of the sli...

Page 15: ...tly via the skimmer in order to facilitate the priming of the pumps until the water level covers all the jet spouts but without reaching the level of the lowest headrest Avoid over filling the spa as...

Page 16: ...Tighten up the coupling and start the pump The pump should prime and air escapes for a moment through the massage nozzles Should the pump not prime quickly stop it and restart the operation Depending...

Page 17: ...access to the spa in the absence of periods of supervision and to protect it from the wind and pollution we advise you to attach the cover with the lockable cleats supplied with it 3 5 Initial treatme...

Page 18: ...ts position a diverter valve directs the flow from the pump to a particular sector Maintaining the diverter valve in an intermediate position between two sectors can create some turbulence in the circ...

Page 19: ...off Waterfall Diverter valve 2 on off Therapy dream collar massage 4 4 MARAMI Diverter valve 1 on off Waterfall Diverter valve 2 on off Therapy dream collar massage Diverter valve 3 on off Foutain jet...

Page 20: ...ncy from your filter it should be filled with silica sand with a grain size classification between 0 5mm and 0 7mm With the quantity indicated on the plate specifying the characteristics proceed as fo...

Page 21: ...cause damage to the filter collector unit RECIRCULATE In this position the selector valve allows the water from the pump to go directly to the spa without passing through the inside of filter FILTER F...

Page 22: ...igh cloudy water Decrease the pH The pressure rises rapidly during a filter cycle Lack of chlorine greenish coloured water Add chlorine The pump is taking in air Check for leaks in the prefilter and s...

Page 23: ...e condition of the joint Motor turning in the wrong direction only for 3 phases pumps Invert the two phases of the feeding line The pump does not prime Hydraulic network not well dimensioning Too much...

Page 24: ...In order to display the temperature press once on the buttons or To change the temperature all you have to do is to press again on the keys or After 5 seconds the display will return to normal provide...

Page 25: ...enced by the presence of a level detector Chromotherapy Press the Light key to switch on the chromotherapy illumination of the spa Press a second time to switch it off It will automatically go off aft...

Page 26: ...which corresponds to a 10h duration of the function It is possible to set the function between 0h and 24h in intervals of one hour To do that all you have to is press the or key during the display of...

Page 27: ...conds until the time displayed starts flashing Use the keys and to set the value of the hour then press again on Clock to change the minutes Likewise use the keys and to set the minutes Lastly validat...

Page 28: ...efore of the need to clean them BEFORE CLEANING THE FILTRATION CARTRIDGES ALWAYS SWITCH OFF THE SPA POWER SUPPLY 5 2 Draining and filling the spa WARNING READ THE FOLLOWING INSTRUCTIONS BEFORE DRAININ...

Page 29: ...atures a slight bleaching of the deepest parts of the tank a variation in the height of the edge of the spa of 6mm slight undulation on the top part due to the shrinkage of the polyester reinforcement...

Page 30: ...pH moves away from this range the more serious the problems will become proportionally A low pH will be corrosive for the metal of the spa equipment A high pH will cause the depositing of minerals on...

Page 31: ...ction of the environment Installation and use This warranty will be null and void for damage resulting from the operation of the spa at a temperature outside the range 1 C to 42 C the operation of the...

Reviews: