43
PARAMETER P10 – MINIMUM FAN SPEED SETTING
6. Use buttons ‘+’ and ‘-’ to modify the value of the parameter be-
tween: min
= 33 Hz ; max = 133 Hz.
The default value is adjusted according to the output set in pa-
rameter P00.
7. Press and release button ‘S’ to con
fi
rm. The parameter number
(P10) will appear on the display .
8. Switch off the appliance and switch it back on again to render the
new parameter operative.
PARAMETER P11 – MAXIMUM FAN SPEED SETTING
6. Use buttons ‘+’ and ‘-’ to modify the value of the parameter be-
tween: min
= value of parameter P10; max = 203 Hz.
The default value is adjusted according to the output set in pa-
rameter P00.
7. Press and release button ‘S’ to con
fi
rm. The parameter number
(P11) will appear on the display.
8. Switch off the appliance and switch it back on again to render the
new parameter operative.
PARAMETER P12 – MINIMUM FAN SPEED SETTING (CENTRAL
HEATING)
6. Use buttons ‘+’ and ‘-’ to modify the value of the parameter be-
tween: min
= 33 Hz ; max = 133 Hz.
The default value is adjusted according to the output set in pa-
rameter P00.
7. Press and release button ‘S’ to con
fi
rm. The parameter number
(P12) will appear on the display.
8. Switch off the appliance and switch it back on again to render the
new parameter operative.
PARAMETER P13 – MAXIMUM FAN SPEED SETTING (CEN-
TRAL HEATING)
6. Use buttons ‘+’ and ‘-’ to modify the value of the parameter be-
tween: min
= value of parameter P12 ; max = 203 Hz.
The default value is adjusted according to the output set in pa-
rameter P00.
7. Press and release button ‘S’ to con
fi
rm. The parameter number
(P13) will appear on the display.
8. Switch off the appliance and switch it back on again to render the
new parameter operative.
P 11
S
S
S
S
P 12
P 10
S
S
S
S
P 13