English
15
몇
Warning
–
When the outgoing air is carried back
into the room, a sufficient ventilation
rate L in the room must be ensured. To
comply with the required limit values the
carried back volume flow must be 50%
of the fresh air volume flow (room vol-
ume V
R
x ventilation rate L
W
) at maxi-
mum. Without a specific ventilation
system the following applies: L
W
=1h
–1
.
–
Only persons trained in the use of the
machine and the handling of substanc-
es for which the machine is to be used
including training in the safe disposal of
the sucked-in material may use the ma-
chine.
–
This appliance contains harmful dust.
Evacuation and maintenance work, in-
cluding the disposal of the dust collec-
tion containers, may only be performed
by specialists who wear the appropriate
protective equipment.
–
Do not use the appliance without the
complete filtering system.
–
Please follow the safety regulations ap-
plicable to the materials that are to be
treated.
The appliance allows 2 operating modes:
1
Industry vacuum cleaner mode (socket
not used)
2
Dedusting mode (socket used)
Connect the suction hose and insert in-
sert the suction nozzle or connect to the
dust-generating device depending on
the operating mode.
몇
Warning
Do not vacuum without the filter elements;
otherwise, the suction motor can get dam-
aged and this can be hazardous to health
on account of increased release of fine dust
particles.
The horn blows when the air speed falls be-
low 20 m/s.
Note:
The horn reacts to negative pres-
sure.
Set the rotary switch to the correct suc-
tion hose cross-section.
Static charge is deflected by providing
earthing to the connection nozzles. This
prevents the formation of sparks and cur-
rent shocks due to attachments (option)
with electrical conductivity.
몇
Warning
Do not use the filters 6.904-212.0 and
6.904-356.0 (special accessory) while
sucking in dusts hazardous to health.
Symbols on the machine
WARNING: This unit contains hazardous
dust. Emptying and maintenance, includ-
ing the removal of the dust bag, may only
be carried out by someone who is familiar
with the unit and wearing suitable protec-
tive gear. Do not switch on the unit until
the complete filter system has been in-
stalled and the function of the volume-
flow control has been tested.
Safety instructions
Start up
Horn
Anti-static system
Dry vacuum cleaning