Flow Sensor Connection
Flow sensor
cables
Power cable
13
Pump
Spacers
Pump spacer connection
Seperate the spacers, remove the adhesive backing and snap into position.
Only remove the
adhesive tab at this
hole.
Any unused sensor wires must be terminated in a connector block and insulated using electrical insulation
tape at a dry location. Failure to do this may damage the pump.
Ensure the pump spacers are used to prevent the cables from being trapped.
Red
Brown
Flow Sensor
Wire
+
S
Black
White
Red
Black
Pump Wire
Connector Block
+
S
-
Red
Brown
Black
Connects to
Connects to
Connects to
Red
White
Black
Flow
Sensor
Pump
All cable connections must be in a dry location.
CONNECTING FLOW SENSOR TO M17 DIGIPUMP
To connect the flow sensor cable directly to a compatible electric shower please see the
instructions supplied with your electric shower.
CONNECTING FLOW SENSOR TO COMPATIBLE SHOWER