background image

www.tmatlantic.com 

 

 

- 1 -

Contents 

. General............................................................................................................................................................................. - 1 - 

. Open-package Inspection................................................................................................................................................. - 1 - 

. Safety Note....................................................................................................................................................................... - 2 - 

. Description of Safety Symbols......................................................................................................................................... - 3 - 

. Description of Instrument Panel and Pushbutton Functions ............................................................................................ - 3 - 

. Other Functions................................................................................................................................................................ - 4 - 

. Property............................................................................................................................................................................ - 4 - 

. DC Voltage (DCV)........................................................................................................................................................... - 4 - 

IX. AC Voltage (ACV)........................................................................................................................................................... - 5 - 
X. DC Current (DCA)............................................................................................................................................................ - 6 - 
XII. Resistance....................................................................................................................................................................... - 7 - 
XIII. Diode and On-and-Off Test........................................................................................................................................... - 7 - 
XIV. Capacity (C) .................................................................................................................................................................. - 8 - 
XV. Frequency (Hz) ............................................................................................................................................................... - 8 - 
XVI.Temperature Measurement............................................................................................................................................. - 9 - 
XVII. Comminication Connection......................................................................................................................................... - 9 - 
XVIII.Instrument Maintenance............................................................................................................................................ - 10 - 

. General 

Endowed with the key touching function instead of the traditional mechanical knobs, is a new type of 3 5/6 digital 
multimeter equipped with the LCD display device with the text height of 33mm which has the merits of visual display, easy 
operation, stable performance and high reliability. It can be used to measure DC voltage, AC voltage, DC current, AC current, 
resistance, capacitance, frequency, temperature, diode and make on-and-off test. Meanwhile, it is available for unit symbol 
display, data retention, the measurement of maximum and minimum value, automatic/manual range switching, automatic 
power off and alarm function. The complete machine takes a switching integrated circuit which can directly drive LCD 
microprocessor and double-integrating A/D and a digital display drive offering high resolution and high precision. Due to it's 
complete functions, high measurement accuracy and convenient operation, the multimeter is the ideal tool in laboratory and 
factory as well as for radio fans and family. 

. Open-package Inspection 

Open the package box and take out the meter, check carefully if the following accessories are absent or damaged. If there is 
any absence or damage, please contact the distributor immediately. 
Digital Multimeter                                                                1 PC 
Instruction Manual                                                                1 copy 
Test Leads                                                                              1 pair 
Temperature Probe (K-Thermocouple)                 1 PC 
PC Interface Cable                                                                1 PC 
Software Disk                                                                        1 PC 
1.5V batteries ("AAA" 7# batteries)                   2 PCs 
Holster                                                                                    1 PC 

Summary of Contents for AM-1171

Page 1: ......

Page 2: ...equency temperature diode and make on and off test Meanwhile it is available for unit symbol display data retention the measurement of maximum and minimum value automatic manual range switching automa...

Page 3: ...measuring point and ensure there is no any signal at the input terminal 6 When the electrical measurement is made never let your body get in touch with the ground directly and don t touch uncovered me...

Page 4: ...e minimum value is held After the MAX MIN mode is entered the display device indicates the MAX MIN value No analog bar display and auto power off function in this working environment Press down MAX MI...

Page 5: ...of 61 analog bars 1 4 Measurement mode dual integration A D conversion 1 5 Sampling rate About 3 time s 1 6 Over range Display OL 1 7 Low voltage display about 2 4v the symbol displayed 1 8 Working t...

Page 6: ...Respectively plug in the red and black meter pens into the terminals of and com See the picture below 2 The initial state of the meter is automatic range which shows AUTO symbol Press the Range key a...

Page 7: ...e maximum input current 10A not exceeding 15s Overload protection 0 6A 250V fuse 10A 250V fuse XI AC Current ACA 1 Press the button or button Plug the black meter pen into the hole of COM and the red...

Page 8: ...eter pens and measure the resistance of the lead wires and then deduct it in the actual measurement Range Accuracy Resolution 600 0 8 5d 0 1 6k 1 60k 10 600k 100 6M 0 8 4d 1k 60M 1 2 10d 10k Open circ...

Page 9: ...equency Hz 1 Press button to conduct frequency measurement Respectively plug in the meter pen into V Hz and COM 2 Have the testing end of the meter pen connected in parallel with the signal sources to...

Page 10: ...the terminals of and COM 3 Put the induction end of temperature probe on the surface of the tested object See the picture on the right 4 Read the current testing results from the display Caution a Wh...

Page 11: ...e steps are as follows 1 Loosen the screw on the back cover that secures the battery door and exit the battery door 2 Remove the 3V batteries and replace them with two new ones Although a 3V battery o...