. Safety Note 

In accordance with IEC1010 clause (the safety standard issued by International Electrotechnical Commission), IT is 
designed and produced according to the safety requirements of pollution level 

 

Warning: 

  In order to avoid endangering the operator’s safety, prior to the operation of the instrument, please read the instruction 

manual carefully, and conform to the safety warning information and operation instruction strictly to use the instrument. 

1.

 

When voltage above 30V, current above 10mA, AC power line with inductive load or power line during electric 
fluctuation is measured, please beware of electric shock. 

2.

 

Prior to measurement, check if the measurement function is in conformity with the LCD display, and if the 
pushbutton switch is at the trigger position. Check if the meter pen is contacted reliably, connected correctly, and 
grounded well and etc. in order to avoid electric shock. 

3.

 

Only if the meter is used with the matched meter pen, can it meet the requirement of safety standard. When the line 
of the meter pen is damaged, it is necessary to replace another one of the same model or the same electrical 
specification. 

4.

 

Don’t use other unconfirmed or disapproved protector tube to replace the protector tube inside the meter. Only the 
protector tube of the same model or same specification can be replaced. Before the replacement, the meter pen must 
leave the measuring point and ensure there is no any signal at the input terminal. 

5.

 

Don’t use other unconfirmed or disapproved battery to replace the battery inside the meter. Only the battery of the 
same model or same electrical specification can be replaced. Before the replacement, the meter pen must leave the 
measuring point and ensure there is no any signal at the input terminal. 

6.

 

When the electrical measurement is made, never let your body get in touch with the ground directly, and don’t touch 
uncovered metal terminal, output port, lead clamp and etc. where earth potential may exist. Dry clothes, rubber shoes, 
rubber cushion and other insulating material are usually used to keep your body insulated against the ground. 

7.

 

Don’t store and use it in the high-temperature, high-humidity, inflammable and strong magnetic field environment. 

8.

 

It may do damage to the meter and endanger the operator’s safety if the voltage value beyond the permitted ultimate 
voltage value is measured. The ultimate voltage value permitted for measurement is marked on the instrument panel, 
and never measure the value exceeding the standard. Don’t input the ultimate value out of regulation in order to 
avoid electric shock and the damage to the meter. 

9.

 

When the meter pen is inserted into the current socket, don’t measure any voltage for fear that the meter should be 
damaged and the operator’s safety be endangered. 

10.

 

Don’t try calibrating or repairing the meter. When it is indeed necessary for that, only the qualified professional 
personnel who have had special training or gained approval can make it. 

11.

 

During measurement, the requirement of measurement function must be in accordance with LCD display. Please be 
sure to disconnect the line of the meter pen with the measured object first and ensure there is no any input signal. It 
is forbidden to switch the function/range selection switch during measurement 

12.

 

When 

“       ”

 

is shown on LCD display, please replace battery immediately to ensure the measurement precision.

 

13.

 

It is not allowed to insert the meter pen into the current terminal to measure voltage! 

14.

 

Please don’t change the circuits of the meter freely for fear that the meter be damaged and the safety be endangered. 

Summary of Contents for AM-1171

Page 1: ......

Page 2: ...equency temperature diode and make on and off test Meanwhile it is available for unit symbol display data retention the measurement of maximum and minimum value automatic manual range switching automa...

Page 3: ...measuring point and ensure there is no any signal at the input terminal 6 When the electrical measurement is made never let your body get in touch with the ground directly and don t touch uncovered me...

Page 4: ...e minimum value is held After the MAX MIN mode is entered the display device indicates the MAX MIN value No analog bar display and auto power off function in this working environment Press down MAX MI...

Page 5: ...of 61 analog bars 1 4 Measurement mode dual integration A D conversion 1 5 Sampling rate About 3 time s 1 6 Over range Display OL 1 7 Low voltage display about 2 4v the symbol displayed 1 8 Working t...

Page 6: ...Respectively plug in the red and black meter pens into the terminals of and com See the picture below 2 The initial state of the meter is automatic range which shows AUTO symbol Press the Range key a...

Page 7: ...e maximum input current 10A not exceeding 15s Overload protection 0 6A 250V fuse 10A 250V fuse XI AC Current ACA 1 Press the button or button Plug the black meter pen into the hole of COM and the red...

Page 8: ...eter pens and measure the resistance of the lead wires and then deduct it in the actual measurement Range Accuracy Resolution 600 0 8 5d 0 1 6k 1 60k 10 600k 100 6M 0 8 4d 1k 60M 1 2 10d 10k Open circ...

Page 9: ...equency Hz 1 Press button to conduct frequency measurement Respectively plug in the meter pen into V Hz and COM 2 Have the testing end of the meter pen connected in parallel with the signal sources to...

Page 10: ...the terminals of and COM 3 Put the induction end of temperature probe on the surface of the tested object See the picture on the right 4 Read the current testing results from the display Caution a Wh...

Page 11: ...e steps are as follows 1 Loosen the screw on the back cover that secures the battery door and exit the battery door 2 Remove the 3V batteries and replace them with two new ones Although a 3V battery o...

Reviews: