Overload protection: 250V DC or AC peak value. 

XIV. Capacity (C) 

1. Press "          " button and respectively plug in the red and black meter pens into “              ”and“COM”. 
2. Circularly press "            " button and select the automatic measurement range of capacity. Meanwhile, the corresponding 

symbol will appear on the LCD screen. No manual measurement range and analog bar will be displayed in Capacity mode. 

Caution

a) When measuring the capacity, all the powers within the tested circuits must be disconnected and the capacitance shall be 

sufficiently discharged 

b)When measuring big capacitors, it takes a longer time, about 100uF per 15 seconds. 
c) When the measurement is completed, immediately disconnect the meter and the measured circuit. 

Range 

Accuracy 

Resolution

40nF 

±(5.0%+30d) 

10pF 

400nF 

100pF 

4μF 

1nF 

40μF 

±(3.5%+8d) 

10nF 

200μF 

±(5.0%+10d) 

100nF 

Overload protection: 250V DC or AC peak value. 

XV. Frequency (Hz) 

1. Press "              " button to conduct frequency measurement.   

Respectively plug in the meter pen into “V

Hz”and“COM”. 

2. Have the testing end of the meter pen connected in parallel with the signal sources to be measured and read the results 

from the display.    (Note: No analog bar will displayed in this mode) 

3. When testing frequency, press "Hz/DUTY" once to conduct duty cycle measurement. Press "Hz/DUTY" once more to   

enter the frequency status.   

4. Read the current results from the display.   

Caution

a) Do not input signals higher than 60V, otherwise it may   

damage the instrument and pose dangers to human safety.     

b) After all the measurements are completed, it is necessary   

to disconnect the meter pen and the tested circuit. 

Range  

Display value 

Measurement 

condition  

   

 

Diode forward 
voltage drop   

Forward DC current 
is about 1.0mA, and 
backward voltage is 
about 3.0V.   

 

If Buzzer emits a 
long sound and the 
resistance of the 
two points is 
measured as 30

 

Open circuit voltage 
is about 1.2V 

 F

 C

Hz

diode

switch

AC

D

C

/

D

C

/AC

 F

 C

H

z

switch

buzzer

AC

D

C

/

D

C

/A

C

switch

 F

 C

H

z

capacitance

AC

D

C

/

D

C

/A

C

Summary of Contents for AM-1171

Page 1: ......

Page 2: ...equency temperature diode and make on and off test Meanwhile it is available for unit symbol display data retention the measurement of maximum and minimum value automatic manual range switching automa...

Page 3: ...measuring point and ensure there is no any signal at the input terminal 6 When the electrical measurement is made never let your body get in touch with the ground directly and don t touch uncovered me...

Page 4: ...e minimum value is held After the MAX MIN mode is entered the display device indicates the MAX MIN value No analog bar display and auto power off function in this working environment Press down MAX MI...

Page 5: ...of 61 analog bars 1 4 Measurement mode dual integration A D conversion 1 5 Sampling rate About 3 time s 1 6 Over range Display OL 1 7 Low voltage display about 2 4v the symbol displayed 1 8 Working t...

Page 6: ...Respectively plug in the red and black meter pens into the terminals of and com See the picture below 2 The initial state of the meter is automatic range which shows AUTO symbol Press the Range key a...

Page 7: ...e maximum input current 10A not exceeding 15s Overload protection 0 6A 250V fuse 10A 250V fuse XI AC Current ACA 1 Press the button or button Plug the black meter pen into the hole of COM and the red...

Page 8: ...eter pens and measure the resistance of the lead wires and then deduct it in the actual measurement Range Accuracy Resolution 600 0 8 5d 0 1 6k 1 60k 10 600k 100 6M 0 8 4d 1k 60M 1 2 10d 10k Open circ...

Page 9: ...equency Hz 1 Press button to conduct frequency measurement Respectively plug in the meter pen into V Hz and COM 2 Have the testing end of the meter pen connected in parallel with the signal sources to...

Page 10: ...the terminals of and COM 3 Put the induction end of temperature probe on the surface of the tested object See the picture on the right 4 Read the current testing results from the display Caution a Wh...

Page 11: ...e steps are as follows 1 Loosen the screw on the back cover that secures the battery door and exit the battery door 2 Remove the 3V batteries and replace them with two new ones Although a 3V battery o...

Reviews: