ASAHI KASEI
[AKD4633-A]
<KM079407>
2016/10
- 36 -
(6-3) [F Response]: [Filter Plot] Dialog Box
The frequency response of digital filter is displayed when push a [F Response] button.
Then, the register setting for digital filter are also updated.
Change Frequency Range, and indication of a frequency characteristic is updated when push a [UpDate] button.
Figure 27. [F Response] Window
[Frequency Range] edit box : The width of the frequency display is specified.
[UpDate] button
: It draws in the graph again.
[Log View] check button
: Switch of “Linear/Log” display.
[Mouse Control of Left Button] radio button
:
The item (fo, Gain) which can be adjusted with a mouse can be chosen. (at using EQx) (
Note 12
)
fo: Center frequency can be adjusted.
Gain: Gain can be adjusted.
fo and Gain: Center frequency and Gain can be adjusted.
[Close] button
: Closing the dialog box and finish the process.
Note 12. EQx of “Notch ON” is able to adjust only “fo”.
~ Adjustment of vertical range ~
1
.
[ Y-axis Ref ] edit box : Display setting of center value.
2
.
[Vertical slider]
: Movement of vertical display.
3
.
[Horizontal slider]
: Adjustment of the horizontal display.
(The left side reduces, and the right side expands.)