operAting the Device
DMM14 MANUAL
124
Step Description
1
Lock the complete unit, to do this press the
SYSTEM CONTROL
rotary knob at the same time as the
OUT
rotary knob for longer than 3 seconds
• The
LOCKED
LED is lit.
• The original settings are stored.
• Turning the rotary knob has no function.
• All other rotary knobs are in
LEVEL
mode and can still be
operated.
2
Remove the lock on all channels by pressing the rotary knob
for the required channels for longer than 3 seconds.
The status conditions that were set before the channels or the complete unit
was locked, are retained even after the DMM14 U (UL, ULD) is switched of
and back on!
8.12
Copying configuration data
The copy function can be used to copy individual or multiple settings
(
LEVEL, TREBLE, BASS, LOWCUT, LIMITER
and
COMPRESSOR
) on an
input to one or more other inputs.
8.12.1 Copying individual values
To copy individual values from one channel to one or more other channels,
proceed as follows:
Step Description
1
Select the required function on the
SYSTEM CONTROL
rotary
knob
2
Press the rotary knob with the value to be copied, then
straight away press the rotary knob up to which the copy
process is to be carried out
Copy
configurations
Summary of Contents for DMM14 U
Page 65: ... DMM14 MANUAL 65 ...
Page 66: ... DMM14 MANUAL 66 ...
Page 130: ... DMM14 MANUAL 130 ...
Page 192: ... DMM14 MANUAL 192 ...
Page 193: ... DMM14 MANUAL 193 ...
Page 259: ... DMM14 MANUAL 259 ...