Ultrasonic Fuel Level Sensor Manual
Updated until firmware 405p & 1.0.3816
- 14 -
Case 3
Correct AKCP Gasket must be used!
Use 5 washers provided, washers must be placed under
screw heads to prevent rubber lid
damage.
Additional Notes
:- There is no minimal distance from the sensor (sender unit) to the surface of
the fuel according the manufacturer information. However, we would recommend a distance of
more than 10cm in order to avoid liquids to be in contact with the sensor or sender unit.
The UFLS must be mounted at least 150mm from a vertical tank baffle, tank walls and piping.
If the fluid splashes on the protrusion head of the UFLS, the UFLS will not be able to measure
correctly the height of fluid in the tank.