background image

formed, which will continue to operate normally and transmit events to the hub. If
the ring is broken, the users and security company receive noti cation.

8. 

Attach the SmartBracket mounting panel to a vertical surface with the
bundled screws. When using other fasteners, make sure they do not
damage or deform the mounting panel. The recommended installation
height is 2.5 meters or more.

Don’t use double-sided adhesive tape for temporary or permanent  xation of the
siren, as the device may come off the surface at any time.

9. 

Place the siren on the SmartBracket mounting panel.

10. 

Secure the siren with a screw. This reduces the risk of burglary and
sabotage. 

11. 

Turn on the hub to supply the connected siren with power. When power is
applied, the siren’s LED frame will notify that the device is turned on.

12. 

.

Add StreetSiren Fibra to the system

13. 

Conduct the Fibra signal strength test. The recommended signal strength
value is two or three bars. Otherwise, check the connection and the
condition of the cable.

14. 

Conduct the 

. If the siren is hard to hear, change the

volume or move the device.

Volume level test

Summary of Contents for StreetSiren Fibra

Page 1: ...tion with other security systems is not provided StreetSiren Fibra only works as a part of the Ajax security system communicating with the hub via the secure Fibra protocol The wired connection range...

Page 2: ...ting and an LED frame for visual alerting StreetSiren Fibra performs two tasks It informs about alarms and indicates the arming mode 1 Informs about alarms The device responds to tamper triggering and...

Page 3: ...to transmit alarms and events This is a two way wired data transfer protocol that provides fast and reliable communication between the hub and the rest of the devices Using the bus connection method...

Page 4: ...ype of the device the name of the device and the virtual room to which the detector is assigned Note that the list of transmitted parameters may differ depending on the type of CMS and the selected pr...

Page 5: ...ations of this manual may result in detector malfunction false alarms or loss of connection with already installed devices When designing the layout scheme of the detectors consider the wiring diagram...

Page 6: ...or breaking the conductor Be sure to check all cables for bends and physical damage before installation Perform the installation in a way that minimizes the possibility of damage to the cables from th...

Page 7: ...ble with future OS Malevich updates Hardware update of Hub Hybrid won t be required Do not install the siren Installation and connection Before installing StreetSiren Fibra make sure that you have sel...

Page 8: ...and regulations for electrical installation work In order to install a siren 1 Disconnect the hub external power supply and the backup battery 1 External power supply 2 Backup battery 2 Run the siren...

Page 9: ...advance The ends of the wires of the first and second cables which will be inserted into the siren terminals must be tinned and soldered together or crimped with special tips 7 If the siren is the las...

Page 10: ...ation of the siren as the device may come off the surface at any time 9 Place the siren on the SmartBracket mounting panel 10 Secure the siren with a screw This reduces the risk of burglary and sabota...

Page 11: ...settings and create at least one PRO version of the app PRO account virtual room 2 Make sure that the hub is turned on and has Internet access via Ethernet and or mobile network You can check the con...

Page 12: ...in the upper left corner of the device icon 1 Open the Select the hub you want to add StreetSiren Fibra to PRO version of the app 2 Go to the Devices tab and click Add device 3 Select Add all bus devi...

Page 13: ...gress StreetSiren Fibra has been temporarily deactivated by a user or PRO with administrator rights StreetSiren Fibra has tamper triggering events temporarily deactivated by a user or PRO with adminis...

Page 14: ...gth Signal strength between the hub and StreetSiren Fibra Recommended values 2 3 bars Fibra protocol for transmitting StreetSiren Fibra events and alarms Learn more in progress Connection via Fibra Th...

Page 15: ...you when the Night mode is switched on and off by flashing an LED and making a short beep Notify on entry exit delay When enabled the siren beeps to signal about a delay when entering leaving Chime o...

Page 16: ...e under the SmartBracket mounting panel Device Siren loop zone number Bus The number of the hub bus the siren is physically connected to Settings To change StreetSiren Fibra settings in the Ajax app W...

Page 17: ...ch the siren is assigned You can select one or all groups Regardless of the group selected the siren will respond to activation and alarms The option is displayed if group mode is enabled on the hub A...

Page 18: ...e the siren if there is no power on the buses When enabled the siren will be activated when a loss of main power is detected Fibra Signal Strength Test Switches the siren to the Fibra signal strength...

Page 19: ...ing the LED and making a short beep The presence brightness of the indication and the volume of the audible signal depend on the siren settings Switching the Night mode on off When enabled the siren n...

Page 20: ...on the siren settings Delay when leaving for the Night mode When enabled the siren beeps once per second to signal about an exit delay in the Night mode The volume of the sound signal depends on the...

Page 21: ...the detector or settings Setting the tamper alarm response The siren can respond to alarms of hub tampers devices and detectors within the system The option is disabled by default The tamper reacts to...

Page 22: ...tion The siren s LED can indicate that an alarm was previously registered in the armed system The featuren functions as follows 2 Select the hub and go to its Settings 3 Select the Service menu 4 Go t...

Page 23: ...ill participate in after alarm indication Go back to Siren Settings The new parameters will be saved 4 Click Back All setting will be applied How to set Chime Chime is a sound signal that notifies abo...

Page 24: ...tegory 6 Set the volume of the beeps 3 options are available Quiet 88 dB at a distance of 1 m Loud 94 dB at a distance of 1 m Very loud 112 dB at a distance of 1 m The specified Beep volume also appli...

Page 25: ...he siren emits a short beeps one The volume of the sound signal depends on the siren settings Security system is disarmed if indication is enabled Blinks twice with the LED and beeps twice The volume...

Page 26: ...unctioning of your siren on a regular basis The optimal frequency of checks is once every three months Clean the siren enclosure from dust cobwebs and other contaminants as they emerge Use a soft dry...

Page 27: ...If the device does not function correctly please contact the Ajax Technical Support first In most cases technical issues can be resolved remotely Contact Technical Support Compliance with standards 1...

Page 28: ...Subscribe to the newsletter about safe life No spam Subscribe Email...

Reviews: