VLnA-B
−
This is the approximate phase to phase line voltage between phases A and B.
VLnB-C
−
This is the approximate phase to phase line voltage between phases B and C.
VLnC-A
−
This is the approximate phase to phase line voltage between phases C and A.
VBus
−
This is the DC bus voltage.
Therm1
−
This is the temperature of the current source primary heatsink.
Therm2
−
This is the temperature of the bridge heatsink.
Therm3
−
This the the temperature of the current source secondary heatsink.
Therm4
−
Open (not used).
Therm5
−
Open (not used).
ExtInt
−
This is the status of the relay contacts for a remote protection device..
OFF
ON
The third diagnostic screen is available by again pressing and holding the Run Status
button and pressing the Parameters
Hz
V
A
kW
button.
This screen displays the values of cycles and running time. Cycle Counts and Run
−
Time can be reset to zero (0). Lifetime Cycles and Lifetime Run
−
Time values cannot be reset.
Cycle Counts.....: 0 CYCLES
Lifetime Cycles..: 0
Run
−
Time.........: 0d 0h 0m 0.0s
Lifetime Run
−
Time: 0d 0h 0m 0.0s
Press the Increase
or Decrease
button simultaneously to reset Cycle Counts and Run
−
Time.
Press Program
to reset cycle counts
Press the Program
button and the cycle counts and run time will be reset to zero (o).