OM-229 158 Page 26
Power....: 0.0 KW
Current..: 0 A
Voltage..: 0 V
Frequency: 4.5 KHz CycleTime: 00:00:00
6-7. Real-Time Operation
Each time the unit is first turned On it initiates a system check routine that includes verification of communication between circuit boards and checking
for output isolation faults. During this check routine, all displays and LEDs illuminate and the following screen appears on the display:
TOCCOtron AC
Firmware Revision OEM 0.52
Copyright (c) 2006
MEM
X.XX indicates the firmware revision number installed in the unit.
If an error is detected during the check routine, the system fault LED illuminates and an error message screen appears on the display (see Section 9-5).
When the check routine is completed successfully, the operator interface defaults to the following:
The Stop
button indicator LED illuminates to indicate no heating cycle is in process.
The display defaults to the Run Status screen from the last program used and the Run Status
button indicator LED illuminates.
If no fault or limit conditions are present, system status lights are not illuminated.
Once set up is complete for the desired program procedure (see Section 6-3), pressing the Run
button will initiate a heating cycle. When a
program run is initiated, the Run
button yellow indicator LED illuminates and the Heat On blue indicator LED illuminates to indicate output is
present to the coil. The cycle will continue until the end of the program is reached or the Stop
button is pressed.
Press the Program
button and the yellow indicator LED will illuminate. The display will change to
show the current mode of operation or the current segment of a Timed Program.
Use the Cursor
button to move the cursor to the parameter that will be changed.
Press the Increase
or Decrease
button to make desired changes.