OM-229 158 Page 11
SECTION 4
−
INSTALLATION
4-1. Serial Number and Rating Label Location
The serial number and rating information for the power source is located on the front
of the machine. Use the rating labels to determine input power
requirements and/or rated output. For future reference, write serial number in space provided on back cover of this manual.
4-2. Specifications
Output
Frequency
Rated Output
Required
Reflective
Inductance
Amperes Input at
Rated Load Output
50 or 60 Hz,
Three-Phase
Overall
Dimensions
Weight
Single
Output
Dual
Output
400 V
460 V
575 V
kVA
kW
5 To 30
kHz
35 kW At
100% Duty
Cycle
350 A
(RMS), 700
V (RMS)
35 kW At
100% Duty
Cycle
700 A
(RMS),
700 V
(RMS)
2.5 To 50
h
60 A
50 A
40 A
39
37
Length: 36-3/4 in.
(993 mm)
Width: 21-1/2 in.
(546 mm)
Height: 29 in.
(737 mm)
227 lb
(103 kg)
Storage Temperature Range:
−
40
F (
−
40
C) to 122
F (50
C)
*While idling
4-3. Selecting A Location
1. Lifting Eye
2. Lifting Forks
Use lifting eye or lifting forks to
move unit.
If using lifting forks, extend forks
beyond opposite side of unit.
3. Line Disconnect Device
Locate unit near correct input
power supply.
!
Special installation may be
required where gasoline or
volatile liquids are present
−
see NEC Article 511 or CEC
Section 20.
3
18 in.
(460 mm)
18 in.
(460 mm)
OR
1
2
Movement
Location And Airflow
804 596-A
12 in.
(305 mm)
12 in.
(305 mm)