20
ELECTRODE CLEANING:
Mix up a solution of 1-part hydrochloric acid to 8 parts water. Submerse the electrode in this
solution. Do not submerse brass terminals.
There will be a reaction as the calcium is dissolved. When the reaction ceases (about 10 min-
utes) rinse the electrode in clean water, wipe the brass terminals dry and check that all calcium
has been dissolved. If not, repeat the process with a new solution.
ELECTRODE REASSEMBLY:
Ensure the silicon seal is still in place on the inside circumference of the electrode cap. Insert
the electrode back into the housing and screw on (clockwise) the locking nut. Plug the elec-
trode lead back on to the electrode terminals and turn on the power to the chlorine generator.
POWER SUPPLY REPAIR/MAINTENANCE:
Do not open, no user serviceable parts inside.
The power supply module and cords attached are to be serviced and/or repaired/replaced only
by qualifi ed electrician or the manufacturer.
If the supply cord is damaged, it shall only be replaced by the manufacturer or its service agent
or similarly qualifi ed person in order to avoid a hazard.
CAUTION:
• When working with acid the use of eye protec-
tion, respirator, and rubber gloves are strongly
recommended.
• Always refer to MSDS when dealing with haz-
ardous chemicals.
• When mixing, add acid to water, but NEVER
water to acid.
Summary of Contents for AutoChlor Classic LS Series
Page 8: ...8 ...
Page 9: ...9 Convenient automatic inline salt water chlorination ...