FITTING THE CHLORINATOR CELL HOUSING
The AutoChlor® salt water cell housing must be plumbed into the return line of the pool filter
system after the filter and any diversion valves. Please refer to the installation diagram and
plumbing outline for the correct method of installation (Fig. 2).
In situations where a heater is incorporated, the AutoChlor® housing must be installed after the
heater. Should a solar heating system be installed, the housing must be plumbed after the solar
diverters and after the water exits the solar system and rejoins the main stream pool return
line.
Please note that your cell housing has been manufactured so that 40 mm PVC pipe will fit both
inlet and outlet ports internally, and 50 mm couplings will fit externally. This allows the use of
either 40 mm or 50 mm PVC pipes in the pool return line.
GAS TRAP
NO GAS TRAP
OK
Fig. 2