PLEASE VERIFY FUEL NOZZLE IS HOUSED WITHIN THE BURNER TUBE OPENING AS OUTLINED IN STEP 4 ON
PAGE 4. SOP-1004A/SOP-1010A SHOULD ONLY BE USED IN PERMANENT INSTALLATION APPLICATIONS
TO CONNECT THE GAS SUPPLY
CAUTION
Griddle must be connected to the
vehicle’s propane
system with a flexible hose connector complying with
the high-pressure requirements of the
Standard for
Pigtails and Flexible Hose Connectors for LP Gas,
ANSI/UL 569
, and shall be of a length no longer
than that required to allow the griddle to be mounted
in the
“in use” position of its mounting system.
The hose must be installed in a manner that will not
allow it to come in contact with the hot surface of the
griddle while in use or in the storage/travel mode.
INSTALLATION
NOTE:
Griddle to be installed on Non-
Combustible materials only.
For permanent installations, griddle must be secured to a
non-combustible material using the 4 bolts, washers and
spacers provided. An example non-combustible mounting
On SOP-1004A/1010A a
3/8” male flare connection
is provided for gas line connection. Some standards
may require the use of a manual shut off valve in the
gas line external to the appliance.
It will be necessary to hold the flare fitting on the griddle
manifold when connecting or loosening the gas line.
For connecting gas supply on SOP1005A/1011A,
refer to figure 10 on page 6.
WARNING
Never check leaks with an open flame. Turn on
the gas and apply soapy water to all joints to see
if bubbles are formed.
surface with mounting holes size and layout is illustrated
in Figure 5. See Figure 6 for assembly of components.
Spacers must be installed between the griddle bottom
and mounting surface. Use of the four mounting holes in
the bottom of the griddle is the only permissible method
for permanently securing the griddle.
NOTE:
For installation on Suburban Outdoor
Kitchen products with raised mounting bosses,
spacers are not required.
(9 29/32")
5/8" MIN
6 17/32"
(2 5/16")
21 1/2"
FRONT OF UNIT
4X 11/32
USE (4) .250" SPACERS PROVIDED WITH UNIT
Figure 5
SPACER
NON-COMBUSTIBLE
SURFACE
WASHER
5
Figure 6
SCREW
MODEL SOP-1004A SOP1005A SOP-1010A SOP-1011A
PERMANENTLY INSTALLED SUBURBAN ELITE
SERIES INSTALLATION INSTRUCTIONS
WARNING
Do not use this appliance under extended awnings.
Failure to comply could result in a fire or personal injury.
The Suburban Elite Series Griddle must be installed on
the opposite side from the fuel distribution/dispensing
system of the recreational vehicle.
Appliance shall not be located or used under overhead
unprotected combustible construction.
When unit is in storage (travel) position, ensure all low-
pressure propane gas system precautions are in place
and all propane gas shut off valves are in the OFF position.
CAUTION
BEFORE YOU BEGIN INSTALLATION
This
appliance
MUST
accommodate
the
recommended minimum clearances to combustible
constructions:
• 6.0” from sides
• 8.0” from back