background image

5

RANGE AND COOKTOP MODEL NUMBERS

17” AND 22” CONVENTIONAL BURNER MERCURY FREE CONTROL RANGES

Model

Number

Burners

Oven

Height

Top         

Porcelain

Door

Top

 Ignition

SRNA3SBBE

3

17”

Black

Black

Piezo

SRNA3SBBM

3

17”

Black

Black

Match

SRNA3SBGE

3

17”

Black

Black w/

Glass

Piezo

SRNA3SBGM

3

17”

Black

Black w/

Glass

Match

SRNA3SPSS

3

17”

Stainless 

1

Stainless

Spark 

2

SRNA3LBBE

3

22”

Black

Black

Piezo

SRNA3LBBM

3

22”

Black

Black

Match

SRNA3LBGE

3

22”

Black 

Black w/

Glass

Piezo

SRNA3LBGM

3

22”

Black

Black w/

Glass

Match

SRNA3LPSS

3

22”

Stainless 

1

Stainless

Spark 

2

17” AND 22” SEALED BURNER MERCURY FREE CONTROL RANGES

Model

Number

Burners

Oven

Height

Top         

Porcelain

Door

Top

 Ignition

SRSA3SBBE

3

17”

Black

Black

Piezo

SRSA3SBBM

3

17”

Black

Black

Match

SRSA3SBGE

3

17”

Black

Black w/

Glass

Piezo

SRSA3SBSE

3

17”

Black

Stainless

Piezo

SRSA3SPSS

3

17”

Stainless 

1

Stainless

Spark 

2

SRSA3LBBE

3

22”

Black

Black

Piezo

SRSA3LBBM

3

22”

Black

Black

Match

SRSA3LBGE

3

22”

Black

Black w/

Glass

Piezo

SRSA3LBSE

3

22”

Black

Stainless

Piezo

SRSA3LPSS

3

22”

Stainless 

1

Stainless

Spark 

2

Porcelain with appearance of stainless steel

Spark igniter requires 1 AAA battery (included)

Summary of Contents for Suburban 2697AST

Page 1: ...RANGE 17 RANGE RANGE W BUILT IN GLASS COVER Technical service information in electronic digital video audio or hard copy format is provided by Airxcel Suburban Division Technical Services Department...

Page 2: ...del Numbers 8 INSTALLATION INSTRUCTIONS Slide In Cooktops and Ranges 9 Drop In Cooktops 10 Cooking Appliance Terminology 17 Manifold Identification Information 18 Burner Identification Information 19...

Page 3: ...Factory Service Department Hotline at 423 775 2131 EXT 7102 and our Customer Service Department at 423 775 2131 EXT 7101 Having an understanding of the appliance sequence of operation and a thorough...

Page 4: ...ance or ordering parts Record the information and retain for future reference Replacement parts can be ordered through your local dealer or Suburban Service Center To obtain information on locating a...

Page 5: ...3 22 Black Black w Glass Match SRNA3LPSS 3 22 Stainless 1 Stainless Spark 2 17 AND 22 SEALED BURNER MERCURY FREE CONTROL RANGES Model Number Burners Oven Height Top Porcelain Door Top Ignition SRSA3S...

Page 6: ...SRNA3LBUEZ 3 22 Black Black with Nickel Handle Piezo 17 AND 22 CONTEMPORARY SEALED BURNER RANGES Model Number Burners Oven Height Top Porcelain Door Top Ignition SRSA3SBVEZ 3 17 Black OPEN GLASS Piez...

Page 7: ...ide in Black Match SCS3BE 3 Slide in Black Piezo SCSA3PS 3 Slide in Stainless1 Spark 2 SLIDE IN AND RANGE BI FOLD COVERS FLUSH MOUNT GLASS COVER Part Number DESCRIPTION 2814A Bi Fold Cover Black NOT S...

Page 8: ...SDN2 Stainless Steel Top Only SDN3 BK 3 SDN2 Black Top Only SDN3 WH 3 SDN2 White Top Only SDS2 2 RV Drop In Cooktop with Stainless Top and Black Glass Cover Flush Mounted DROP IN COVERS DESCRIPTION 2...

Page 9: ...ound the gas lines are sealed at the time of installation WARNING It is imperative that the cabinet in which the unit is placed be separated from other appliances so that the combustion air supply to...

Page 10: ...net in which the unit is placed be separated from other appliances so that the combustion air supply to the top burners can not be affected in any way by any forced air heating appliance or its return...

Page 11: ...TAGE PLAN DE TRAVAIL MUR LATERAL MUR ARRIERE DU BRULEUR DU BRULEUR 2 13 16 4 3 8 D B D C E GAS SERVICE PIPE OPENING MIN DIM TO EITHER SIDE WALL MIN DIM TO BACK WALL MOUNTING HOLES A DEGAGEMENT DE SECU...

Page 12: ...rated from other appliances so that the combustion air supply to the top burners can not be affected in any way by any forced air heating appliance or its return air system or by any other source of p...

Page 13: ...er ignition source an explosion and or fire will occur resulting in property damage personal injury and or loss of life 9 Be sure all openings in the cabinets around the gas line are sealed at time of...

Page 14: ...35 135 SDS2 3 If any burner should extinguish after initial lighting or due to accidental blow out turn gas off by turning control knob clockwise to OFF wait five 5 minutes before attempting to religh...

Page 15: ...fice holder 7 Loosen nut retaining thermocouple using an 8 mm wrench Pull thermocouple quick connector free from appropriate gas valve 8 Pull wire free from ignition module 9 Spread bottom of electrod...

Page 16: ...113 18 813 478 GAS CONNECTION BATTERY HOLDER 12VDC 12VDC TERMINAL CONNECTION Electrode 2 Ignition Module Ignition Switch R Bk Bk Y G Y G Touch Safe Terminal Block Bk 12 VDC IN FIELD WIRING FACTORY WI...

Page 17: ...AT The control that regulates the temperature of the oven at the preferred cooking temperature and supplies gas for both the pilot burner and oven burner PIEZO IGNITER An electromechanical device that...

Page 18: ...ntly along with Sabaf manifolds on all conventional and sealed burner model ranges from late 2006 through mid 2009 Used exclusively on all conventional burner model ranges N in the model number from m...

Page 19: ...ice at 423 775 2131 EXT 7101 If a replacement is required for BSI Mueller style burner you will need to order KIT 521119 and replace all three burners BURNER BTU OUTPUT INFORMATION RANGE TOP BURNER Le...

Page 20: ...rmocouple models only D Inspect micro switch adjust as required MAIN BURNER WON T LIGHT A No gas flowing to main burner A Inspect burner orifice for obstruction Inspect gas pressure to main burner rep...

Page 21: ...tles which may become lodged in the orifice or burner ports and cause a fire or explosion B Insufficient gas pressure B Inspect propane supply inspect for gas leaks have propane pressure inspected by...

Page 22: ...ore the oven burner will operate the oven pilot must be lit 1 Lighting Oven Pilot a Be sure ALL valves are in the OFF position The oven control knob should be in the OFF position b Be sure main gas su...

Page 23: ...ANTY IS GIVEN SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS SO THE ABOVE LIMITATIONS MAY NOT APPLY TO YOU THE EXPRESSED WARRANTIES MADE IN THIS WARRANTY ARE EXCLUSIVE AND...

Page 24: ...AIRXCEL INC SUBURBAN DIVISION 676 Broadway Street Dayton Tennessee 37321 423 775 2131 Fax 423 775 7015 www Airxcel com Email SMCSales SuburbanMfg com...

Page 25: ...appliances and components found on RVs was something that I always had a desire to create I hope this resource makes your RV repairs easier as it has mine but please be careful and follow proper safe...

Reviews: