5-2
PERFORMANCE DATA & PRESSURE CURVES
SM FBFRPM 1-A.0 GB
5.1.2
Heating Mode at 7.5m Tubing Connection.
230V : Indoor Fan at High Speed.
ENTERING AIR
WB OU COIL (
°
C)
ENTERING AIR DB ID COIL (
°
C)
15
20
25
TH
PI
TH
PI
TH
PI
-10
4.73 2.24 4.55 2.39 4.37 2.51
-7
5.09 2.30 4.91 2.42 4.73 2.55
-2
5.40 2.32 5.22 2.46 5.04 2.60
2
6.57 2.44 6.30 2.59 6.03 2.74
6
9.27 2.62
9.00 2.80
8.69 2.97
10
10.08 2.76 9.81 2.95 9.54 3.16
15
10.89 2.88 10.62 3.11 10.35 3.30
20
11.48 2.97 11.21 3.22 10.89 3.47
*
the above chart includes the weighted deicing infleuence.
LEGEND
TH – Total Heating Capacity, kW
PI
– Power Input, kW
WB –
Wet Bulb Temp., (
o
C)
DB – Dry Bulb Temp., (
o
C)
ID – Indoor
OU –
Outdoor
5.2
Capacity Correction Factor Due to Tubing Length (One Way)
TOTAL TUBING LENGTH
4m
7.5m
10m
15m
20m
25m
30m
40m
50m
1.01
1
0.98
0.97
0.96
0.95
0.94
---
---
*
Minimum recommended tubing length between indoor and outdoor units is 4m.
5.2.1 Heating
TOTAL TUBING LENGTH
4m
7.5m
10m
15m
20m
25m
30m
40m
50m
1.02
1
0.99
0.99
0.98
0.97
0.97
---
---
*
Minimum recommended tubing length between indoor and outdoor units is 4m.
Summary of Contents for YCF055
Page 45: ...8 2 WIRING DIAGRAMS SM FBFRPM 1 A 0 GB 8 3 Indoor Units YDF030 8 4 Outdoor Unit GCN 30NRCT...
Page 46: ...8 3 WIRING DIAGRAMS SM FBFRPM 1 A 0 GB 8 5 Outdoor Unit GCN 37NRC 8 6 Outdoor Unit GCN 37NRCT...
Page 47: ...8 4 WIRING DIAGRAMS SM FBFRPM 1 A 0 GB 8 7 Outdoor Unit YDF047 8 8 Outdoor Unit YCF055...
Page 50: ...10 2 REFRIGERATION DIAGRAMS SM FBFRPM 1 A 0 GB 10 1 2 FBF045 FBF060...
Page 92: ...14 4 EXPLODED VIEWS AND SPARE PARTS LISTS SM FBFRPM 1 A 0 GB 14 4 Indoor Unit FBF046 FBF060...
Page 109: ...15 3 OPTIONAL ACCESSORIES SM FBFRPM 1 A 0 GB 15 3 RCW RCW2 Wiring Connections as Shown on Kit...