5-
29
PERFORMANCE DATA & PRESSURE CURVES
Revision 0
5.2
4
.2
Heating Mode at 7.5m Tubing Connection.
230V : Indoor Fan at High Speed
.
ENTERING AIR DB ID COIL ( °C)
15
20
25
ENTERING AIR WB
OU COIL (°C)
TH
PI
TH
PI
TH
PI
-10
4.87 2.60 4.68 2.77 4.50 2.91
-7
5.24 2.67 5.05 2.81 4.87 2.96
-2
5.56 2.70 5.38 2.86 5.19 3.02
2
6.77 2.83 6.49 3.01 6.21 3.19
6
9.55 3.04
9.27 3.25
8.95 3.45
10
10.38 3.21 10.10 3.43 9.83 3.67
15
11.22 3.35 10.94 3.61 10.66 3.84
20
11.82 3.45 11.54 3.74 11.22 4.03
*
the above chart includes the weighted deicing infleuence.
LEGEND
TH –
Total Heating Capacity, kW
PI
– Power Input, kW
WB –
Wet Bulb Temp., (
o
C)
DB –
Dry Bulb Temp., (
o
C)
ID
–
Indoor
OU –
Outdoor
5.2
5
Capacity Correction Factor Due to Tubing Length
5.2
5
.1 Cooling
TOTAL TUBING LENGTH (One Way)
3m
7.5m
10m
15m
20m
25m
30m
40m
50m
1.12
1
0.979
0.943
0.940
0.931
0.913
---
---
*
Minimum recommended tubing length between indoor and outdoor units is 3m.
TOTAL TUBING LENGTH (One Way)
3m
7.5m
10m
15m
20m
25m
30m
40m
50m
1.01
1
0.987
0.969
0.952
0.935
0.927
---
---
*
Minimum recommended tubing length between indoor and outdoor units is 3m.
Summary of Contents for ONG 12
Page 4: ......
Page 19: ...4 1 OUTLINE DIMENSIONS Revision 0 4 OUTLINE DIMENSIONS 4 1 FLO N 7 9 12 14 4 2 FLO N 18 24...
Page 20: ...4 2 OUTLINE DIMENSIONS Revision 0 4 3 FLO N 30 4 4 ONG 7 9 12 14 RC 150m m...
Page 22: ...4 4 OUTLINE DIMENSIONS Revision 0 4 7 OU7 24 RC 4 8 GC 30 N RC...
Page 23: ...4 5 OUTLINE DIMENSIONS Revision 0 4 9 OU8 30 RC...
Page 60: ...8 2 WIRING DIAGRAMS Revision 0 8 2 Indoor Unit FLO 18 24 N LCD...
Page 61: ...8 3 WIRING DIAGRAMS Revision 0 8 3 Indoor Unit FLO 30 N...
Page 63: ...8 5 WIRING DIAGRAMS Revision 0 8 6 Outdoor Unit ONG7 1PH R410A...
Page 64: ...8 6 WIRING DIAGRAMS Revision 0 8 7 Outdoor Unit OU7 24 OU8 30 1PH R410A...
Page 66: ...8 8 WIRING DIAGRAMS Revision 0 8 10 Outdoor Unit OU8 33 3PH R410A...
Page 68: ...9 2 ELECTRICAL CONNECTIONS Revision 0 9 3 FLO 30 N 3PH...
Page 70: ...10 2 REFRIGERATION DIAGRAMS Revision 0 10 1 2 FLO 9 12 14 N R410A...
Page 72: ...10 4 REFRIGERATION DIAGRAMS Revision 0 10 1 4 FLO 24 N R410A...
Page 135: ...14 3 OPTIONAL ACCESSORIES Revision 0 14 3 RCW RCW2 Wiring Connections as Shown on Kit...
Page 137: ...15 5 OPTIONAL ACCESSORIES Revision 0...
Page 138: ...15 6 OPTIONAL ACCESSORIES Revision 0...
Page 139: ...15 7 OPTIONAL ACCESSORIES Revision 0...
Page 140: ...15 8 OPTIONAL ACCESSORIES Revision 0...
Page 141: ......