12a-12
CONTROL SYSTEM
Revision
0
12A.6. Heating
Mode
112Α.6.1. Heating Mode - General
•
Compensation Procedure:
The compensation procedure comes to solve the problem of the temperature
distribution by height during heat mode according to this procedure.
•
When I feel is OFF during heat mode: RT= RAT – CTV.
When I feel is ON during heat mode: RT= RCT.
•
CTV
is a compensation temperature value to be used from the following table (CTV
table).
•
RCV
is a reference compensation value (relation between cells).
•
IOC
is a compensation value when IFAN is OFF.
•
The values of RCV and IOC to be set in the following table are taken from the RCV
and IOC table below depending on the model.
CTV table:
I IFAN
ICT
OFF
LOW
MEDIUM
HIGH
40 >
ICT
IIOC
RRCV+0
RRCV+0
RRCV+0
50 >
ICT
≥ 40
IIOC
RRCV+0
RRCV+0
RRCV+0
ICT
≥ 50
IIOC+1
RRCV+1
RRCV+1
RRCV+1
RCV and IOC table
•
The following table includes the RCV and IOC default values. These values are
set as values in the above compensation table.
Model
RCV
IOC
FLO
30
N +
2
o
C
+2
o
C
WNG-28
+2
o
C
+2
o
C
WNG-25
+2
o
C
+2
o
C
No compensation will be activated in Forced operation modes.
Summary of Contents for ONG 12
Page 4: ......
Page 19: ...4 1 OUTLINE DIMENSIONS Revision 0 4 OUTLINE DIMENSIONS 4 1 FLO N 7 9 12 14 4 2 FLO N 18 24...
Page 20: ...4 2 OUTLINE DIMENSIONS Revision 0 4 3 FLO N 30 4 4 ONG 7 9 12 14 RC 150m m...
Page 22: ...4 4 OUTLINE DIMENSIONS Revision 0 4 7 OU7 24 RC 4 8 GC 30 N RC...
Page 23: ...4 5 OUTLINE DIMENSIONS Revision 0 4 9 OU8 30 RC...
Page 60: ...8 2 WIRING DIAGRAMS Revision 0 8 2 Indoor Unit FLO 18 24 N LCD...
Page 61: ...8 3 WIRING DIAGRAMS Revision 0 8 3 Indoor Unit FLO 30 N...
Page 63: ...8 5 WIRING DIAGRAMS Revision 0 8 6 Outdoor Unit ONG7 1PH R410A...
Page 64: ...8 6 WIRING DIAGRAMS Revision 0 8 7 Outdoor Unit OU7 24 OU8 30 1PH R410A...
Page 66: ...8 8 WIRING DIAGRAMS Revision 0 8 10 Outdoor Unit OU8 33 3PH R410A...
Page 68: ...9 2 ELECTRICAL CONNECTIONS Revision 0 9 3 FLO 30 N 3PH...
Page 70: ...10 2 REFRIGERATION DIAGRAMS Revision 0 10 1 2 FLO 9 12 14 N R410A...
Page 72: ...10 4 REFRIGERATION DIAGRAMS Revision 0 10 1 4 FLO 24 N R410A...
Page 135: ...14 3 OPTIONAL ACCESSORIES Revision 0 14 3 RCW RCW2 Wiring Connections as Shown on Kit...
Page 137: ...15 5 OPTIONAL ACCESSORIES Revision 0...
Page 138: ...15 6 OPTIONAL ACCESSORIES Revision 0...
Page 139: ...15 7 OPTIONAL ACCESSORIES Revision 0...
Page 140: ...15 8 OPTIONAL ACCESSORIES Revision 0...
Page 141: ......