Product specification
4
General Information
3. Product specification
Model Outdoor Unit
JOAU-ZCY218-H11
Installation Method of Pipe
2 x JOSI-DKH009-N11
Installation Method of Pipe
Flared
Characteristics
Units
Cooling
Heating
Average
Capacity
(1)
kW
5.2
6
Pdesign
kW
5.2
5.6
SEER / SCOP
(2)
W/W
5.6
3.8
Energy efficiency class
A+
A
Annual energy consumption
kWh
325
2063
Tbiv
o
C
N/A
-7
Tol
o
C
N/A
-15
Power supply
V/Ph/Hz
220-240V/Single/50Hz
Circuit breaker rating
A
25
Rated power input (Maximum power input)
kW
3.2
Rated current (Maximum current)
A
14.5
OUTDOO
R
Refrigerant control
CaEXV
Compressor type. model
Twin Rotary DC Inverter
Fan type & quantity
Axial x 1
Fan speeds
H/L
RPM
750
Air flow
H/L
m3/hr
2500
Sound power level
(4)
H/L
dB(A)
65
Sound pressure level
(5)
H/L
dB(A)
55
Dimensions
WxHxD
mm
845x700x320
Weight
kg
48
Package dimensions
LxWxH
mm
965x395x755
Packaged weight
kg
52
Stacking height
units
2 levels
Refrigerant type
R410A
Refrigerant charge (standard connecting
tubing length)
kg(10m)
1.9
Additional charge per 1 meter
gr / 1m
10m<L<20m 15g/m
Connection
s between
units
Liquid line
In.(mm)
2x1/4”(Φ6.35)
Suction line
In.(mm)
2x3/8”(Φ9.52)
Max. length for all rooms
m
30
Max. length for one indoor unit
m
20
Max.
height
difference
between
indoor and
outdoor
unit
OU higher than IU
m
10
OU lower than IU
m
15
Max. height difference between
indoor units
m
10
Operation control type
Remote control
Summary of Contents for johnson JOAU-ZCY218-H11
Page 13: ...Indoor Units Indoor Units 11 Part 2 Indoor Units DKH Type 12 Light Commercial 22 ...
Page 36: ...Dimensions 34 Indoor Units ...
Page 38: ...Service Space unit mm 36 Indoor Units 3 3 Console ...
Page 40: ...Wiring Diagrams 38 Indoor Units JOSI DCD012 N11 JOSI DAQ012 N11 ...
Page 51: ...Dimensions 50 Outdoor Units JOAU ZCY536 H11 ...
Page 55: ...Wiring Diagrams 54 Outdoor Units 4 Wiring Diagrams JOAU ZCY218 H11 JOAU ZCY327 H11 ...
Page 56: ...Wiring Diagrams Outdoor Units 55 JOAU ZCY430 H11 JOAU ZCY536 H11 ...