PERFORMANCE DATA & PRESSURE CURVES
SM HAFRPM 1-A.3 GB
5.11.2
Heating Mode at 7.5m Tubing Connection.
230V : Indoor Fan at High Speed.
ENTERING AIR
WB OU COIL ( °C)
ENTERING AIR DB ID COIL ( °C)
15
20
25
TH
PI
TH
PI
TH
PI
-10
1.82
0.81
1.75
0.86
1.68
0.90
-7
1.96
0.83
1.89
0.87
1.82
0.92
-2
2.08
0.84
2.01
0.89
1.94
0.94
2
2.53
0.88
2.43
0.93
2.32
0.99
6
3.57
0.94
3.47
1.01
3.35
1.07
10
3.89
1.00
3.78
1.07
3.68
1.14
15
4.20
1.04
4.09
1.12
3.99
1.19
20
4.42
1.07
4.32
1.16
4.20
1.25
*
the above chart includes the weighted deicing infleuence.
LEGEND
TH – Total Heating Capacity, kW
PI
– Power Input, kW
WB –
Wet Bulb Temp., (
o
C)
DB – Dry Bulb Temp., (
o
C)
ID – Indoor
OU –
Outdoor