5-13
PERFORMANCE DATA & PRESSURE CURVES
SM HAFRPM 1-A.3 GB
5.7
Model: HAF 7 / GCN 7
5.7.1
Cooling Mode at 7.5m Tubing Connection.
230V : Indoor Fan at High Speed.
ENTERING AIR
DB OD COIL (°C)
DATA
ENTERING AIR WB/DB ID COIL ( °C)
15/21
17/24
19/27
21/29
23/32
15
(1)
TC
2.22
2.30
2.36
2.41
2.45
SC
1.63
1.70
1.76
1.81
1.84
PI
0.44
0.44
0.44
0.44
0.44
20
(1)
TC
2.15
2.27
2.34
2.39
2.45
SC
1.59
1.68
1.75
1.80
1.83
PI
0.48
0.48
0.48
0.48
0.48
25
TC
2.04
2.20
2.31
2.38
2.44
SC
1.55
1.65
1.74
1.79
1.82
PI
0.52
0.52
0.52
0.53
0.53
30
TC
1.90
2.07
2.24
2.32
2.39
SC
1.50
1.60
1.70
1.75
1.78
PI
0.56
0.56
0.57
0.57
0.58
35
TC
1.76
1.91
2.11
2.22
2.32
SC
1.43
1.53
1.66
1.71
1.74
PI
0.60
0.61
0.62
0.62
0.63
40
TC
1.60
1.75
1.90
2.08
2.19
SC
1.35
1.45
1.57
1.62
1.65
PI
0.65
0.66
0.67
0.68
0.68
46
TC
1.39
1.52
1.67
1.85
1.99
SC
1.24
1.33
1.43
1.48
1.51
PI
0.71
0.72
0.73
0.74
0.75
LEGEND
TC –
Total Cooling Capacity, kWv
SC – Sensible Capacity, kW
PI – Power Input, kW
WB – Wet Bulb Temp., (
o
C)
DB – Dry Bulb Temp., (
o
C)
ID – Indoor
OD –
Outdoor
(1) Marked area is below standard operating limits. For operating in low ambient
conditions, refer to Optional Accessories (Chapter 15).
CONTENTS