![Airwell 7SP091170 Service Manual Download Page 6](http://html1.mh-extra.com/html/airwell/7sp091170/7sp091170_service-manual_2879972006.webp)
Product specification
4
General Information
3. Product specification
Model Outdoor Unit
AWAU-YCZ218-H11(7SP091170)
Model Indoor Unit
2 x AWSI-HND009-N11
2 x AWSI-HKD009-N11
Installation Method of Pipe
Flared
Flared
Characteristics
Units
Cooling
Heating
Cooling
Heating
Average
Average
Capacity
(1)
kW
5.3
6.0
5.3
6
Pdesign
kW
5.3
5.5
5.3
5.0
SEER / SCOP
(2)
W/W
7.4
4.0
6.1
3.8
Energy efficiency class
A++
A+
A+
A
Annual energy consumption
kWh
251
1855
304
1842
Tbiv
o
C
N/A
-7
N/A
-7
Tol
o
C
N/A
-15
N/A
-15
Power supply
V/Ph/Hz
220-240V/Single/50Hz
Circuit breaker rating
A
25
Rated power input (Maximum power input)
kW
2.7
Rated current (Maximum current)
A
13.6
O
UTDO
O
R
Refrigerant control
CaEXV
Compressor type. model
Rotary DC Inverter
Fan type & quantity
Axial x 1
Fan speeds
H/L
RPM
750
Air flow
H/L
m3/hr
2500
Sound power level
(4)
H/L
dB(A)
63
Sound pressure level
(5)
H/L
dB(A)
55
Dimensions
WxHxD
mm
845x702x363
Weight
kg
48
Package dimensions
LxWxH
mm
965x395x755
Packaged weight
kg
52
Stacking height
units
2 levels
Refrigerant type
R410A
Refrigerant charge (standard connecting
tubing length)
kg(15m)
2.0
Additional charge per 1 meter
gr / 1m
15m<L<30m 15g/m
Connection
s between
units
Liquid line
In.(mm)
2x1/4”(Φ6.35)
Suction line
In.(mm)
2x3/8”(Φ9.52)
Max. length for all rooms
m
30
Max. length for one indoor unit
m
20
Max. height
difference
between indoor
and outdoor unit
OU higher
than IU
m
10
OU lower
than IU
m
15
Max. height difference between
indoor units
m
10
Operation control type
Remote control
Summary of Contents for 7SP091170
Page 16: ...Indoor Units 14 Indoor Units Part 2 Indoor Units HKD Type 15 HND Type 28 Light Commercial 41...
Page 28: ...Exploded View and Spare Part list 26 Indoor Units 4 7 Exploded view of model AWSI HKD024 N11...
Page 33: ...Dimensions Indoor Units 31 For AWSI HND012 N11 For AWSI HND018 N11 For AWSI HND024 N11...
Page 37: ...Exploded View and Spare Part list Indoor Units 35 4 3 Exploded view of model AWSI HND012 N11...
Page 39: ...Exploded View and Spare Part list Indoor Units 37 4 5 Exploded view of model AWSI HND018 N11...
Page 41: ...Exploded View and Spare Part list Indoor Units 39 4 7 Exploded view of model AWSI HND024 N11...
Page 45: ...Features Indoor Units 43 Dimension 75mm Fresh Air...
Page 50: ...Dimensions 48 Indoor Units 2 Dimensions 2 1 Four way cassette type compact 270...
Page 52: ...Dimensions 50 Indoor Units 2 3 Console...
Page 54: ...Service Space 52 Indoor Units 3 3 Console...
Page 57: ...Wiring Diagrams Indoor Units 55 4 5 AWSI DCD012 N11...
Page 58: ...Wiring Diagrams 56 Indoor Units 4 6 Model AWSI DID012 N11...
Page 59: ...Wiring Diagrams Indoor Units 57 4 7 AWSI XAD012 N11 4 8 Model AWSI XBD012 N11...
Page 72: ...Exploded View and Spare Part list 70 Indoor Units 5 13 Exploded view of model AWSI DID012 N11...
Page 74: ...Exploded View and Spare Part list 72 Indoor Units 5 15 Exploded view of model AWSI XBD009X N11...
Page 87: ...Wiring Diagrams Outdoor Units 85 4 Wiring Diagrams 4 1 AWAU YCZ218 H11 4 2 AWAU YCZ327 H11...
Page 88: ...Wiring Diagrams 86 Outdoor Units 4 3 AWAU YCZ430 H11...
Page 89: ...Wiring Diagrams Outdoor Units 87 AWAU YCZ542 H11 7SP091173...
Page 151: ...Electrical Control System 149 SERVICE MANUAL Multi Splits Series...