7
5.1 Initial Light Conditions
When power is initially applied to the hob, the touch
control conducts a calibration process for the touch
keys, which requires a low level of ambient light in
the area of the touch keys. If during the calibration
process excessive ambient lighting is detected the
user interface displays
“
FL
”
(Infrared Ambient Light
Error) and the control calibration is suspended. In
order to rectify the process any lighting that could
affect the calibration process should be switched off
(e.g. halogen cooker hood lighting). The error will
disappear when satisfactory ambient lighting is
detected and the touch control calibration
procedure will now complete satisfactorily.
−
The
“
FL
”
error can only be generated within
approx. 3s of initial power being applied to
the hob.
−
We recommend that the user switches off
all cooker hood lighting and lighting
directed towards the hob when power is
initially applied to the hob.
−
After the touch control has conducted its
initial calibration process, (approx. 3s) any
cooker hood or other lighting can be
switched on as normal and will not affect
the operation of the touch control.
5.2 Basic Control Functions
•
The
control
allows
different
layout
configurations.
•
Full induction hobs with 3 or 4 zones.
•
Keylock function.
•
Fast boil function.
•
Stop & Go function.
•
Independent timer for each zone.
•
Indication of residual heat for each zone.
•
Thermal control protection.
•
Protection from accidental activation of keys:
One or more keys activated for more than
10 sec
-
> Switching off the touch control. A
warning beep sounds every 10 sec, while
the key/s is/are activated.
With all zones at zero power during 10 sec
-
> the Hob is switched off. If the switching
off is due to an accidental activation of
keys, the touch control actuates as above.
•
Acoustic warning to attract the user
’
s attention.
•
Pan detection for induction zones; After 60 sec
with no pan, the heater switches off.
1
2
3
4
5
6
6
6
6
7
8
8
8
8
9
10
11
12
Infrared Keys
①
ON_OFF_KEY
②
KEYLOCK_KEY
③
STOP_GO_KEY
④
Timer Minus Key
⑤
Timer Plus Key
⑥
ZONE_n_KEY
⑦
SLIDER
Displays and LEDs
⑧
4 x 7 segment Zone Displays
⑨
2 x 7 segment Timer displays and 5 x LEDs
⑩
Keylock LED
⑪
Stop & Go LED
⑫
Power Level Bargraph LED