Chapter

 

8

 

Appendix

 

A:

 

Server

 

Sensor

 

Mutual

 

Authentication

 

The

 

Sensor

Server

 

communication

 

begins

 

with

 

a

 

mutual

 

authentication

 

step

 

in

 

which

 

the

 

Sensor

 

and

 

Server

 

authenticate

 

each

 

other

 

using

 

a

 

shared

 

secret.

 

Sensor

Server

 

communication

 

takes

 

place

 

only

 

if

 

this

 

authentication

 

succeeds.

 

Once

 

authentication

 

succeeds,

 

a

 

session

 

key

 

is

 

generated.

 

All

 

communication

 

between

 

the

 

Sensor

 

and

 

Server

 

from

 

this

 

point

 

on

 

is

 

encrypted

 

using

 

the

 

session

 

key.

  

The

 

Sensor

 

and

 

Server

 

are

 

shipped

 

with

 

the

 

same

 

default

 

value

 

of

 

the

 

shared

 

secret.

 

The

 

CLI

 

commands

 

are

 

provided

 

on

 

both

 

Server

 

and

 

Sensor

 

for

 

changing

 

the

 

shared

 

secret.

 

Note:

 

Once

 

the

 

shared

 

secret

 

(communication

 

key)

 

is

 

changed

 

on

 

the

 

Server,

 

all

 

Sensors

 

connected

 

to

 

the

 

Server

 

will

 

automatically

 

be

 

setup

 

to

 

use

 

the

 

new

 

communication

 

key.

 

Sensors

 

that

 

are

 

not

 

connected

 

to

 

the

 

Server

 

at

 

this

 

time

 

will

 

need

 

to

 

be

 

setup

 

with

 

the

 

same

 

communication

 

key

 

for

 

them

 

to

 

be

 

able

 

to

 

communicate

 

with

 

this

 

Server.

 

 

Note:

 

While

 

the

 

Server

 

is

 

backward

 

compatible,

 

that

 

is,

 

pre

 

version

 

6.7

 

Update

 

1

 

Sensors

 

can

 

connect

 

to

 

a

 

version

 

6.7

 

Update

 

1

 

Server,

 

this

 

is

 

not

 

recommended.

 

Once

 

all

 

Sensors

 

have

 

been

 

upgraded

 

to

 

version

 

6.7

 

Update

 

1,

 

the

 

set

 

sensor

 

legacy

 

authentication

 

CLI

 

command

 

can

 

be

 

used

 

to

 

disable

 

older

 

Sensors

 

from

 

connecting

 

to

 

the

 

Server.

 

 

Summary of Contents for SS-300-AT-C-60

Page 1: ...Tight Networks Inc 339 N Bernardo Avenue 200 Mountain View CA 94043 http www airtightnetworks com Product documentation is being enhanced continuously based on customer feedback To obtain a latest cop...

Page 2: ...This page has been intentionally left blank...

Page 3: ...SS 300 AT C 60 Access Point Sensor InstallationGuide...

Page 4: ...FOR ANY DAMAGE OR VIOLATION OF GOVERNMENT REGULATIONS ARISING FROM YOUR USAGE OF THE PRODUCT EXPECT AS EXPRESSLY DEFINED IN THE INDEMNITY SECTION OF THIS DOCUMENT LIMITATION OF LIABILITY AirTight wil...

Page 5: ...llowing two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation RF exposure wa...

Page 6: ...conditions d exposition des appareils mobiles les antennes se situent moins de 20 cm du corps d une personne FCC NOTICE To comply with FCC part 15 rules in the United States the system must be profess...

Page 7: ...SS 300 AT C 60 with power adapter 10 CHAPTER 5 MANUALLY CONFIGURING THE SS 300 AT C 60 AS SENSOR 12 5 1 INTRODUCTION 12 5 2 CONFIGURING SENSOR THROUGH CONFIG SHELL 12 5 2 1 Invoke HyperTerminal or min...

Page 8: ...E SENSOR 9 FIGURE 9 HOLES FOR INSERTING SCREWS 9 FIGURE 10 POWER UP AND CONNECT SS 300 AT C 60 USING POE 10 FIGURE 11 POWER UP SS 300 AT C 60 10 FIGURE 12 CONNECT SS 300 AT C 60 TO THE NETWORK 11 FIGU...

Page 9: ...rs Package Contents Lists the components included in the system package SS 300 AT C 60 Overview Provides an overview of sensor Installing the device Describes how to connect and install SS 300 AT C 60...

Page 10: ...on how it is configured Please ensure that the following items are included in the SS 300 AT C 60 device package If the package is not complete please contact AirTight Networks Inc Technical Support a...

Page 11: ...e Only LED1 LED2 LED3 and LED4 are in use The following table indicates various device states using the LEDs on the device when the device is in AP mode Table 1 LED details for SS 300 AT C 60 in AP mo...

Page 12: ...link Slow Blink The Sensor upgrade is in progress Solid Orange Any Any Solid Green The Sensor is unable to get Ethernet link Solid Orange Any Any Fast Blink The Sensor did not receive a valid IP addre...

Page 13: ...02 3af standard Figure 3 Rear Panel of SS 300 AT C 60 Table 4 Rear Panel Port Settings for SS 300 AT C 60 Port Description Connector Type Speed Protocol Ethernet LAN1 This enables the device to be con...

Page 14: ...to the default wifi security server All the VLAN configurations are lost Device mode is changed to Sensor Only If static IP was configured on the device the IP is erased and DHCP mode is set After re...

Page 15: ...ported if the following conditions are satisfied The device is in Sensor mode A DNS entry wifi security server is set up on all DNS Servers This entry should point to the IP address of the Server By d...

Page 16: ...t in the same position as shown above Clip the metal ceiling bracket to a suitably located ceiling tile separator Figure 6 Clipping the Metal Ceiling bracket Slide the movable section into place and t...

Page 17: ...serting screws Connect the Ethernet cable for power and network connection to the LAN port on the back of the device To mount the SS 300 AT C 60 device onto the mounting bracket insert the mounting br...

Page 18: ...e 10 Power up and connect SS 300 AT C 60 using PoE 4 2 4 Using SS 300 AT C 60 with power adapter To power up the device perform the following steps 1 Plug the power cable into the DC power receptacle...

Page 19: ...ensor list command You will see a list of all Sensors that are recognized by the SpectraGuard Enterprise server The Sensor is configured and ready to go Check the Console to ensure that this Sensor ha...

Page 20: ...llations Sensor is placed on a subnet that is not DHCP enabled 5 2 Configuring Sensor through Config Shell To use the Config Shell connect a Serial RS 232 cable between your computer and the Sensor Th...

Page 21: ...ide Figure 14 Opening HyperTerminal Note If you are using a Linux laptop you can use minicom to connect to the Config Shell 5 2 1 2 Defining a New HyperTerminal Connection Figure 15 Define a New Hyper...

Page 22: ...n the Connection Description dialog 5 2 1 3 Specifying HyperTerminal Connection Details Figure 16 Specify HyperTerminal Connection Details Select or enter the appropriate connection details Click OK o...

Page 23: ...iguration in the Spectraguard Enterprise User Guide for more details Recommended AirTight recommends that you change the default password for security reasons although it is not mandatory 5 2 3 Set Se...

Page 24: ...set mode command to set the device mode for SS 300 AT C 60 Figure 19 set sensor mode command for SS 300 AT C 60 5 2 5 Configure Network Settings Once the mode is set you have to enable the Network Set...

Page 25: ...ays the Server discovery setting information get status Displays the current running status of all the components get version Displays the version and build information of all the components get vlan...

Page 26: ...n 10 and 127 as the shared secret The string is internally converted to hexadecimal format It can be used instead of the set communication key command Table 3 Miscellaneous commands Other Commands Com...

Page 27: ...sure that the traffic is allowed on UDP port 3851 If utilizing the Server ID based discovery ensure that multicast is enabled on the network Alternatively if utilizing the Server IP based discovery en...

Page 28: ...ng the Server IP based discovery ensure that the DNS name wifi security server has been correctly entered on the DNS Server Also ensure that the DNS Server IP addresses are either correctly configured...

Page 29: ...ecret The CLI commands are provided on both Server and Sensor for changing the shared secret Note Once the shared secret communication key is changed on the Server all Sensors connected to the Server...

Reviews: