8
3.
Connections and elements of the RE-46 PROFINET
3.1 Connections of the RE-46 PROFINET (Front view)
1
Flange header M12 5-pin A-coded (POWER)
Pin
Designation
Description
1
+24V
Supply voltage for bus electronics
Fuse: 1A slow blow
2
+24V_1
Supply voltage for valves 1-12 (solenoids1-24)
1
Fuse: 3,15A slow blow
3
GND
Ground for +24V, +24V_1, +24V_2
4
GND
Ground for +24V, +24V_1, +24V_2
5
+24V_2
Supply voltage for valves 13-24 (solenoids 25-48)
2
Fuse: 3,15A slow blow
2
+
3
Flange receptacle M12 4-pin D-coded (PROFINET Port 1 + Port 2)
Pin
Designation
Description
1
TD+
Transmit Data +
2
RD+
Receive Data +
3
TD-
Transmit Data -
4
RD-
Receive Data -
1
This pin should be powered always. Otherwise the solenoids will not work.
2
This pin has to be powered if the valve terminal has more than 12 valve stations. Otherwise it is not necessary to apply
power.
1
2
3
6
4
7
5
8
9