7
2.
Electrical data
RE-46 PROFINET
Parameter
Value
Valve Stations
6, 8, 10, 12 ... 24
Fieldbus connectors
2 x M12 5-pin female D-coded
Power connector
M12 5-pin male A-coded
Power consumption (each sole-
noid)
1 W (solenoid) plus 0,3 W for the status LED
Power consumption of the
fieldbus system
2,9 W at 24 V DC
Address setting
DHCP / manually by DCP-Protocol
Voltage
DC 24 V ±10%
Total current
No valves activated: approx. 120 mA
Valves activated: depending on the numer acti
vated valves
Bitrate
100 Mbit/s (Fast-Ethernet)
Status indicators at the fieldbus
system
24V_1 (LED Green)
24V_2 (LED Green)
24V_3 (LED Green)
P1 L/A (LED Green)
P2 L/A (LED Green)
MD OK (LED Green)
MD ERR (LED Red)
FB OK (LED Green)
FB ERR (LED Red)
Status indicators at the valves
14/12 (LED Yellow) solenoid active
Summary of Contents for RE-46