AS W i p LL 900 MHz
Quick In stallation & Co nfigu ration Gu id e
13070311-02
Airspan Networks Inc.
13
Cabling
This chapter describes BSR, SPR, and IDR Ethernet and serial cabling.
6.1. BSR-to-BSDU Cabling
The BSR interfaces with the provider’s backbone through the BSDU (or SDA). The BSR connects to the BSDU
using a CAT 5 cable. (The BSR-to-SDA cabling is the same as SPR-to-SDA cabling. See Section
6.2.)
Connector pinouts:
Straight-through CAT-5 UTP PVC 4Pair 24 AWG cables
BSR
BSDU/SDA
15-pin
D-type male
Pin
Function
Wire color
Wire
pair
Pin
Function
15-pin
D-type
male
1 +48
VDC
Blue
/
White
1
+48
VDC
2 48
RTN
Blue
1
2 48
RTN
3 Tx+
Orange
/
White
3
Rx+
4 Tx-
Orange
2
4 Rx-
5 Rx+
Green
/
White
5
Tx+
6 Rx-
Green
3
6 Tx-
7 Sync.+
Brown
/
White
7
Sync.+
8 Sync.-
Brown
4
8 Sync.-
Cable connection:
1. Connect the
15-pin D-type male
connector to the BSR’s 15-pin port.
2. Connect the
15-pin D-type male
connector, at the other end of the CAT 5 cable, to one of the BSDU’s
15-pin D-type ports labeled
BSR
, located on the BSDU’s rear panel.