Quick In stallation & Co nfigu ration Gu id e
AS W i p LL 900 MHz
20
Airspan Networks Inc.
13070311-02
Initial Configuration
To successfully establish an air and network link between the BSR and SPRs/IDRs, the following initial
configuration settings (using WipConfig) must exist:
Correct
IP
and
subnet addresses
configured (according to your network addressing scheme)
Correct
BSR's Air MAC
address configured for BSR
Correct
BSR's Air MAC
address assigned to SPRs/IDRs
Identical
frequency table
configured for BSR and SPRs/IDRs
Identical
maximum transmission rate
configured for BSR and SPRs/IDRs
Identical mode (i.e.
router
or
bridge
) configured for BSR and SPRs/IDRs
Notes:
1) For establishing a link in bridge mode,
ensure IP addressing scheme enables IP connectivity between PC
and devices.
2) For establishing a link in router mode, refer to the
ASWipLL Commissioning Manual
.
8.1. Default Settings
Airspan’s factory default settings for the ASWipLL devices are listed in the following table:
Parameter
Default value
IP address:
•
BSR
•
SPR/IDR
•
BSDU
•
10.0.0.10
•
10.0.0.20
•
10.0.0.5
Subnet mask
(BSR, SPR/IDR, and BSDU)
255.255.255.240
Air subnet address
(applicable only in router mode)
192.168.0.0 (e.g. RFC 1918)
Gateway IP address
0.0.0.0
Get Community string
Public
Set Community string
Private
Mode
(bridge or router)
Router
8.2. BSR Initialization
To perform BSR initial configuration:
1. Connect the PC running WipConfig to the BSR using serial cabling.
2. Start WipConfig.
3. On the toolbar, in the
Communication
group, select the
Serial
option, and then click the
Connect
button;
WipConfig connects to the BSR.
8