AirStar 1900/1200 5G Sub-6 GHz Full gNB/RDU
2T2R Indoor Radio Unit – Installation Guide
© Copyright Airspan Networks Ltd., 2022
P/N:
DUG01084
Rev. A0.6, Mar 2022
12
4
AirStar 1900/1200 5G Sub-6 Installation
AirStar 1900/1200 5G Sub-6 supports Ceiling (conventional and suspended) and Wall mounting.
4.1
Ceiling Mount
The following defines the AirStar 1900/1200 ceiling-mount assembly procedure for conventional
ceiling or suspended ceilings.
Prior to assembly, in any mounting scenario, determine where the unit it to be installed.
4.1.1
Conventional Ceiling Assembly
The following are instructions for assembly to a conventional ceiling.
1.
Select the required location where the AirStar 1900/1200 unit is to be installed, on the ceiling
opposite a window.
2.
Position the Ceiling adaptor bracket on the ceiling. Be sure to position the Ceiling adaptor
so the
unit will be opposite a window.
3.
Mark the screw positions carefully through the holes in the Ceiling adaptor bracket onto the
ceiling.
4.
After drilling holes and inserting approved ceiling anchors (plugs) fasten the Ceiling adaptor
bracket to the ceiling with screws and washers (not included).
Screws and washers (x4) and any necessary hardware are not supplied by Airspan and are
the responsibility of the installer. Use appropriate ceiling hardware according to field
conditions. The holes in the Ceiling adaptor are 5/16 (8mm).
Figure 3: Fasten the Ceiling Adaptor Bracket to the Ceiling
5.
Slide the Hanger onto the pole, till the bottom.