Trouble Diagnosis Guide
Trouble Diagnosis
In the event you experience problems with the operation of your Airocide®
System, refer to the following guides:
AiroCide System Operating Status
Green Red Yellow Blue
Action Required
Light Indicators
Power On - Normal Operating Conditions
Lamp Change Required
Outer Cover Off or Not Attached Properly
AiroCide System Overheat
On
On
On
On
Off
Off
Off
Flashing
Off
Flashing
Off
Off
On
On
Off
Off
No Action Required, Normal Operation
Contact Service Technician or
Perform Lamp Change
Ensure outer cover is properly secured
The AiroCide System has exceeded the
maximum operating temperature range.
Contact service technician for diagnostic
testing.
Problem
Solution
- Make certain power cord is plugged in
- Make certain Power switch is in the “On” position
- Make certain Reaction Chamber Access Door is closed
- Make certain Outer Cover is secured properly
- Check Large Particulate Collection Screen for blockage
- Clean the Screen, if necessary
AiroCide System Will Not Power On
- No lights on User Interface Panel
Unit Status Lamp is Off
Air Flow Seems Diminished
Unit Status Indicator Lights – Trouble Diagnosis Guide