background image

SI-104 

 

 

Smoke Sensor 

User Manual 

Summary of Contents for Z-Wave Plus SI-104

Page 1: ...SI 104 Smoke Sensor User Manual ...

Page 2: ...effort to ensure the accuracy of the information in this user s guide However we are not liable for the inaccuracies or errors in this guide Please use with caution All information is subject to change without notice This product contains some codes from GPL In compliance with GPL agreement AirLive will publish the GPL codes on our website Please go to www airlive com and go to the Support GPL men...

Page 3: ...let on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired opera...

Page 4: ...on 3 1 3 Z WaveTM Message Report 3 1 4 Power Up Procedure 4 1 5 Over The Air OTA Firmware Update 4 1 6 Security Network 5 1 7 Test Alarm 5 1 8 Tamper Switch Feature 6 1 9 Battery Installation 6 1 10 Choosing a Suitable Location 6 1 11 Installation 7 1 12 Z Wave Configuration Settings 8 1 13 Z Wave Supported Command Class 9 1 14 Specifications 9 ...

Page 5: ......

Page 6: ...he technology uses a low power RF radio embedded or retrofitted into home electronics devices and systems such as lighting home access control entertainment systems and household appliances This product can be included and operated in any Z WaveTM network with other Z WaveTM certified devices from other manufacturers and or other applications All non battery operated nodes within the network will ...

Page 7: ...ler entered inclusion mode 2 Pressing tamper key three times within 1 5 seconds to enter the inclusion mode 3 After add successful the device will wake to receive the setting command from Z WaveTM controller about 20 seconds Remove 1 Have Z WaveTM Controller entered exclusion mode 2 Pressing tamper key three times within 1 5 seconds to enter the exclusion mode Node ID has been excluded Reset Notic...

Page 8: ...0 hours And the interval step is 30 minutes If the user wants to wake up the device immediately please press the tamper key once The device will wake up 10 seconds 1 3 Z WaveTM Message Report When the smoke sensor detects the device will report the trigger event and also report the battery status In default the device will using Notification Report to represent the trigger event it can be changed ...

Page 9: ...e tamper status 1 4 Power Up Procedure 1 4 1 NWI When the device power on the device will check is it already adding to the network If doesn t press the button to start the NWI mode Until timeout or the device successful to inclusion by controller NWI mode can be aborted by pressing the button 3 times 1 4 2 Wake When the device power on the device will wake about 20 seconds In this duration the co...

Page 10: ...CLASS_WAKE_UP_V2 1 7 Test Alarm Test the sensor by pushing firmly on the test button for around 2 seconds until the horn sounds the sound pattern is 3 beeps pause and then 3 beeps with red LED flashing continuously and rapidly and the controller will receive Smoke alarm test notification If the Smoke Sensor beeps three with yellow LED flashing three times in 43 seconds it indicates the Smoke Senso...

Page 11: ...ttery type is CR123A 3 0V The way to open the front cover please follow below steps 1 Open battery compartment 2 Install battery into compartment and make sure the and ends of each battery are aligned properly 3 After battery is installed in compartment you will hear a chirp which indicates the device is receiving battery power 1 10 Choosing a Suitable Location For complete coverage in residential...

Page 12: ...es hot water heaters and space heaters Do not install Smoke Sensors less than 20 feet 6 meters away from places where combustion particles are normally present like kitchens If a 20 foot distance is not possible e g in a mobile home try to install the alarm as far away from the combustion particles as possible preferably on the wall To prevent nuisance alarm alarms provide good ventilation in such...

Page 13: ... turn it clockwise to fix it into the place Pull onward on the Smoke Sensor to make sure it is securely attached to the mounting bracket 1 12 Z Wave Configuration Settings Notice All of the configuration the data size is 1 The configuration mark with star means after the remove the setting still keep don t reset to factory default Unless the user execute the RESET procedure The reserve bit or not ...

Page 14: ...MAND_CLASS_CONFIGURATION COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 COMMAND_CLASS_VERSION_V2 COMMAND_CLASS_SENSOR_BINARY_V2 COMMAND_CLASS_WAKE_UP_V2 COMMAND_CLASS_ASSOCIATION_GRP_INFO COMMAND_CLASS_POWERLEVEL COMMAND_CLASS_DEVICE_RESET_LOCALLY COMMAND_CLASS_SECURITY COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2 1 14 Specifications Power by CR123A lithium battery Signal Frequency SI 104 868 40 MHz 869 85 MHz EU ...

Page 15: ... AirLive SI 104 User Manual 10 For indoor use only Specifications subject to change without notice due to continuing product improvement OvisLink Corp http www airlive com TEL 886 2 2218 6888 FAX 886 2 2918 6988 ...