Cleanup
22
3A4147B
Cleanup
1.
Perform
Pressure Relief Procedure
,
page 13, steps 1 - 4. Remove tip guard
from gun.
NOTE
: Use water for water-base material,
mineral spirits for oil-base material, or other
solvents recommended by manufacturer.
2.
Turn power
ON
. Turn prime valve
forward to SPRAY position.
3.
Increase pressure to 1/2. Hold gun
against pail. Disengage trigger lock.
Trigger gun until flushing fluid appears.
4.
Move gun to waste pail, hold gun against
pail, trigger gun to thoroughly flush
system. Release trigger and engage
trigger lock.
5.
Turn prime valve down to DRAIN position
and allow flushing fluid to circulate until
flushing fluid appears clear.
6.
Turn prime valve forward to SPRAY
position. Trigger gun into flushing pail to
purge fluid from hose.
7.
Raise pump above flushing fluid and run
sprayer for 15 to 30 seconds to drain
fluid. Turn power OFF.
8.
Turn prime valve down DRAIN position.
Unplug sprayer.
ti22943a
ti22944a
ti18249a
ti18248a
ti22945a
ti22946a
ti18248a
ti29682a
ti22945a