Switch Tip Installation
18
3A4147B
Switch Tip Installation
1.
Perform
Pressure Relief Procedure
,
page 13.
2.
Use spray tip (A) to insert OneSeal
™
(B)
into guard (C).
3.
Insert Switch Tip.
4.
Screw assembly onto gun. Tighten.
Spray
1.
Spray test pattern. Increase pressure to
eliminate heavy edges. Use smaller tip
size if pressure adjustment can not
eliminate heavy edges.
2.
Hold gun perpendicular, 10-12 in. (25-30
cm) from surface. Spray back and forth.
Overlap by 50%. Trigger gun after
moving and release before stopping.
Clearing Tip Clogs
1.
Release trigger, engage trigger lock.
Rotate Switch Tip. Disengage trigger
lock. Trigger gun to clear clog.
2.
Engage trigger lock. Return Switch Tip to
original position. Disengage trigger lock
and continue spraying.
ti29398a
ti29399a
ti293400a
ti18243a
To avoid serious injury, never point gun at
your hand or into a rag.
ti18242a
ti29401a
ti29402a