background image

Troubleshooting 

14

3A1174B

Speed of application slow or slower

New pump hose not broken in 
properly

Run pump dry for no more than 2 
minutes.

Material too thick

Thin material. 

Nozzle too small

Change nozzles to a larger size. See 
Recommended Nozzle Selection 
Chart, page 11
.

Too much air being used

Partially close gun air valve to reduce 
air flow.

Pump hose worn 

Replace hose.

Plugged or dirty gun

Relieve Pressure, page 7. Clean 
gun.

Kinked hose

Unkink hose.

Gun adjustment set too low

Increase flow adjustment with flow 
adjustment nut.

Too many items on same circuit

Unplug other items from circuit

Extension cord too long or wrong 
gauge

Use a different extension cord. Refer 
to Grounding and Electric Require-
ments, page 7
.

Intermittent flow/sputtering

Hopper connection not tight

Check gasket. TIghten connection.

Debris in system

Clean system.

Quick disconnect does not stay con-
nected.

Dirty or corroded fitting

Clean thoroughly. Soak in oil. Apply a 
few drops of light oil.

Gun will not shut off

Worn nozzle or needle

Relieve Pressure, page 7. Replace 
worn parts.

Debris in needle passage

Relieve Pressure, page 7. Clean.

Fluid leaking at Flow Adjustment Nut Damaged seal

Relieve Pressure, page 7. Replace 
seal.

Fluid leaking out of either plug

Missing or damaged o-rings

Relieve Pressure, page 7. Replace 
o-rings.

Gun damaged

Replace gun.

Needle adjustment won’t adjust

Dirty threads

Clean threads.

Nozzle not on gun

Put nozzle on gun.

Problem

Cause

Solution

Summary of Contents for 24F565

Page 1: ...proved to European explosive atmosphere requirements 24F565 50 psi 35 MPa 3 5 bar Maximum Fluid Working Pressure 100 psi 7 MPa 7 bar Maximum Air Input Pressure Related Manuals Important Safety Instruc...

Page 2: ...lectric shock When repair or replacement of the cord or plug is required do not connect the grounding wire to either flat blade terminal The wire with insulation having an outer surface that is green...

Page 3: ...fire extinguisher in the work area ELECTRIC SHOCK HAZARD This equipment must be grounded Improper grounding setup or usage of the system can cause electric shock Turn off and disconnect power cord be...

Page 4: ...r to pressures in excess of those specified by Airlessco Do not use the hose as a strength member to pull or lift the equipment PLASTIC PARTS CLEANING SOLVENT HAZARD Many solvents can degrade plastic...

Page 5: ...rial line from sprayer 2 Tip sprayer up as shown Before adding material or starting unit in cold weather run warm water through pump Before adding material to hopper install burp guard J When only a s...

Page 6: ...Pump Hose Outlet J Burp Guard B RotoFlex II Pump inside K ON OFF Switch C Texture Spray Gun Manual 311969 L Power Cord 120V 15 ft D Nozzle 2 included see Nozzle Selection page 11 M Material Hopper 5 g...

Page 7: ...it will not fit the outlet have proper outlet installed by a qualified electrician 120V AC Systems This equipment requires a 120V AC 60 Hz 15A cir cuit with a grounding receptacle Do not use an adapt...

Page 8: ...le See Recommended Nozzle Selection Chart page 11 NOTE To break in new pump run dry for no more than 2 minutes 6 Fill material hopper with 1 gallon of water 7 Turn power switch K ON leave compressor O...

Page 9: ...material sprays out of gun 12 Turn on Air compressor and open gun valve to desired setting 13 To achieve uniform spray pattern adjust air valve and flow adjustment nut on gun If you can not achieve a...

Page 10: ...t be sure gauge is com pletely dry and clean every time it is used 5 Observe the ball on the material When the material is thin enough to spray the ball will sink completely into the mixture 6 If the...

Page 11: ...ow through pump Set air compression at a minimum of 25 psi Addi tional air pressure may be needed for thicker materi als or when product is applied to ceilings To Get Less Material Try one or a combin...

Page 12: ...re residue Flush with water 10 Turn air compressor OFF NOTE Inspect slots under machine daily for texture material If you find material flowing out of slots or see material inside unit replace pump ho...

Page 13: ...ure page 7 Remove gun from hose Clean gun Pump hose worn out Replace hose Recommended hose replacement once every year Pump cold Move pump to warm room and allow it to warm up or run hot water through...

Page 14: ...wrong gauge Use a different extension cord Refer to Grounding and Electric Require ments page 7 Intermittent flow sputtering Hopper connection not tight Check gasket TIghten connection Debris in syst...

Page 15: ...AWG 3 wire 15 ft Material Hopper Capacity 5 gallons Maximum Delivery with Texture 0 65 gpm TS650 Dimensions and Weight Length 19 in 482 mm with handle Width 12 in 305 mm Height no handle 20 in 508 mm...

Page 16: ...replace free of charge any defective parts The equipment will be returned to the original purchaser transportation prepaid If inspection of the equipment does not disclose any defect in material or wo...

Reviews: