Problem

Cause

Solution

Sprayer won’t run

Power switch not on

Turn switch on.

No power at wall outlet

Check outlet by plugging in another 
appliance. If appliance does not 
work, try another outlet.

Wrong size generator

Use a 3500 watt or larger generator. 
Refer to Generator Requirements, 
page 7
.

Breaker tripped

Reset breaker.

Pump won’t pump material

Air lock

Open air valve on gun.

Mix too thick

Add water to thin material. Use Mate-
rial Thickness Gauge.

Loose fittings

Check and retighten all fittings.

Plugged gun

Relieve Pressure, page 7. Remove 
gun from hose. Clean gun.

Pump hose worn out

Replace hose. Recommended hose 
replacement - once every year.

Pump cold

Move pump to warm room and allow 
it to warm up or run hot water through 
sprayer.

Material runs out of bottom of sprayer Pump hose worn out

Replace hose.

Loose fittings

Check and retighten all fittings.

No air from compressor

Gun air valve closed

Open gun air valve.

Low voltage

Check extension cord length and 
gauge. Replace if different than rec-
ommended. Refer to Grounding and 
Electrical Requirements, page 7
.

Gun needle plugged

Clean needle and retry.

Worn compressor

Replace compressor. Contact an 
authorized Airlessco Service Center.

Lines not connected

Check all quick disconnect connec-
tions to gun and hoses.

Damaged hose

Replace hose.

Summary of Contents for 24F565

Page 1: ...proved to European explosive atmosphere requirements 24F565 50 psi 35 MPa 3 5 bar Maximum Fluid Working Pressure 100 psi 7 MPa 7 bar Maximum Air Input Pressure Related Manuals Important Safety Instruc...

Page 2: ...lectric shock When repair or replacement of the cord or plug is required do not connect the grounding wire to either flat blade terminal The wire with insulation having an outer surface that is green...

Page 3: ...fire extinguisher in the work area ELECTRIC SHOCK HAZARD This equipment must be grounded Improper grounding setup or usage of the system can cause electric shock Turn off and disconnect power cord be...

Page 4: ...r to pressures in excess of those specified by Airlessco Do not use the hose as a strength member to pull or lift the equipment PLASTIC PARTS CLEANING SOLVENT HAZARD Many solvents can degrade plastic...

Page 5: ...rial line from sprayer 2 Tip sprayer up as shown Before adding material or starting unit in cold weather run warm water through pump Before adding material to hopper install burp guard J When only a s...

Page 6: ...Pump Hose Outlet J Burp Guard B RotoFlex II Pump inside K ON OFF Switch C Texture Spray Gun Manual 311969 L Power Cord 120V 15 ft D Nozzle 2 included see Nozzle Selection page 11 M Material Hopper 5 g...

Page 7: ...it will not fit the outlet have proper outlet installed by a qualified electrician 120V AC Systems This equipment requires a 120V AC 60 Hz 15A cir cuit with a grounding receptacle Do not use an adapt...

Page 8: ...le See Recommended Nozzle Selection Chart page 11 NOTE To break in new pump run dry for no more than 2 minutes 6 Fill material hopper with 1 gallon of water 7 Turn power switch K ON leave compressor O...

Page 9: ...material sprays out of gun 12 Turn on Air compressor and open gun valve to desired setting 13 To achieve uniform spray pattern adjust air valve and flow adjustment nut on gun If you can not achieve a...

Page 10: ...t be sure gauge is com pletely dry and clean every time it is used 5 Observe the ball on the material When the material is thin enough to spray the ball will sink completely into the mixture 6 If the...

Page 11: ...ow through pump Set air compression at a minimum of 25 psi Addi tional air pressure may be needed for thicker materi als or when product is applied to ceilings To Get Less Material Try one or a combin...

Page 12: ...re residue Flush with water 10 Turn air compressor OFF NOTE Inspect slots under machine daily for texture material If you find material flowing out of slots or see material inside unit replace pump ho...

Page 13: ...ure page 7 Remove gun from hose Clean gun Pump hose worn out Replace hose Recommended hose replacement once every year Pump cold Move pump to warm room and allow it to warm up or run hot water through...

Page 14: ...wrong gauge Use a different extension cord Refer to Grounding and Electric Require ments page 7 Intermittent flow sputtering Hopper connection not tight Check gasket TIghten connection Debris in syst...

Page 15: ...AWG 3 wire 15 ft Material Hopper Capacity 5 gallons Maximum Delivery with Texture 0 65 gpm TS650 Dimensions and Weight Length 19 in 482 mm with handle Width 12 in 305 mm Height no handle 20 in 508 mm...

Page 16: ...replace free of charge any defective parts The equipment will be returned to the original purchaser transportation prepaid If inspection of the equipment does not disclose any defect in material or wo...

Reviews: