8.
Take the three Belleville Springs (187-031) and slide
over the top of the piston in the following order:
* First spring, curve facing down
* Second spring, curve facing up
* Third spring, curve facing down
9.
Take the upper male gland (187-025) and place it with
the rounded side up.
10.
Take the three upper polyethylene V-packings (187-030)
and two leather packings (187-060) and assemble with
the inverted side down , on to the male gland in the
following order:
polyethylene, leather, polyethylene, leather, polyethylene.
11.
Take the upper female gland (187-026) & place on top of
your assembled upper packings with the inverted side
down.
12.
Take your assembled upper glands and packings (7
pieces) and slide on over the top of the piston, making
sure the inverted sides are facing down.
13.
Take the V-packing holder (187-047) and replace the
white O-ring (106-012) and the black O-ring (106-013)
with new ones from the packing kit.
14.
Slide the V-packing holder over the top of the upper
packings so they fit inside.
15.
Lubricate the inside of the fluid pump body and the out-
side of the packings with a light weight oil.
16.
Slide the completed assembly into the fluid pump body.
* To keep packings secured in the correct position, hold
the pump body upside down and push the completed
assembly upwards into the pump body. Once placed
inside, tilt the pump body back up to keep all pieces in.
PACKING REPLACEMENT (Continued)
187-030
Upper Polyethylene
V-Packings
187-031
Belleville Springs
187-315
810/1110 Spacer
187-037
Lower Male Gland
187-029
Lower Polyethylene
V-Packings
187-058
Female Adaptor
187-029
Lower Polyethylene
V-Packings
187-037
Lower Male Gland
187-059
Lower Leather
V-Packings
187-025
Upper Male Gland
187-060
Upper Leather V-Packings
187-026
Upper Female Gland
17.
Thread the packing nut (187-046) into the top of the fluid
body and tighten hand tight.
18.
Take the suction retainer (187-016) and replace the black
O-ring (106-014) with a new one from the packing kit.
Replace the suction ball (187-020) with the new one from
the kit into the suction retainer. Place the suction seat
(187-065) into the flat side of the ball guide, over the
suction ball. Now place the white O-ring (106-017) into
the groove around the suction seat.
19.
Take the completed suction valve assembly and place
it into the bottom of the fluid body, with the rounded side
fitting inside.
20.
Take the suction seat support (187-017) and place the flat
side down on to the suction valve assembly (threads will
be facing upwards).
21.
Thread the suction nut (187-018), over the suction seat
support.
22.
Tighten the packing nut (utilizing the packing nut
adjustment tool) clockwise one full turn.
FIG. 9
(
( (
19
187-015
1500 Space
r
Summary of Contents for 1110E
Page 24: ...22 SL1500 Pump Parts Diagram 3...