1. Overview
AirLive SA-102 User Manual
15
MULTI_CHANNEL_CMD_ENCAP
Source End Point = 0x03
(Meter report = Endpoint3)
(Bit Destination End Point = 0x05) (Bit Address =0
;
Destination End Point =
command inquirer’s Endpoint value)
Command Class = 0x32
(Command_Class_Meter_V3 = 0x32)
Command =0x02
(Meter_Report = 0x02)
Parameter 1 = 0xA1
(Scale Bit2 = 1, Rate Type = 0x01, Meter
Type=0x01)
Parameter 2 = 0x51
(Precision = 2, Scale Bit1Bit0 = 0x10,
Size
= 1)
Parameter 3 = 0x63
Power Factor = 0x63 = 0.99
1.6.5. Z-Wave’s Configuration
Configuration
Parameter
Function
Size
(Byte)
Value
Unit
Default Description
1
Watt Meter
Report Period
2
0x01-
0x7FFF
5s
720
720*5s=3600s=1
hour
2
KWH Meter
Report Period
2
0x01-
0x7FFF
10min 6
6*10min= 1 hour
3
Selected Relay 1
1-3
3
1
:
Relay1
2
:
Relay2
3
:
Relay1 & Relay2
4
Edge or Pulse
mode or
Edge-Toggl e
mode
1
1-3
1
1
:
Edge mode
2
:
Pulse mode
3
:
Edge-Toggle
mode
5
Threshold of
current for
Load Caution
2
10-750
0.01A
750
750*0.01A = 7.5A
6
Threshold of
KWH for Load
Caution
2
1-1000
0
1KWh 10000
7
Restore switch
state mode
1
0-2
1
0 : Switch off
1 : Last switch state
2 : Switch on
8
Auto off timer
2
0-0x7F
FF
1s
0
0 : Disable
auto off function
1-0x7FFF : 1s ~
32767s
9
RF off
command
mode
1
0-3
0
0 : Switch off
1 : Ignore
2 : Switch toggle
3 : Switch on
10
Existence of
Endpoint3
1
1-2
1
1 : Endpoint3 exist
2 : No Endpoint3
1.6.5.1. att Meter Report Period