1. Overview
AirLive SA-102 User Manual
2
1.2 Auto Inclusion
The function of auto inclusion will be executed as long as the in wall switch does not have
Node ID and just connect the switch to main power.
Note:
Auto inclusion timeout is 2 minute during which the node information of explorer
frame will be emitted once every several seconds. Unlike “inclusion” function as shown in
the table below, the execution of auto inclusion is free from pressing the On/Off button on
the Switch.
The table below lists an operation summary of basic Z-Wave functions. Please refer to the
instructions for your Z-WaveTM Certificated Primary Controller to access the Setup function,
and to include/exclude/associate devices.
Function
Description
Annotation
No node ID
The Z-Wave Controller does not
allocate a node ID to the Switch.
LED 2-second on, 2-second
off
Inclusion
1. Put your Z-Wave controller into
inclusion mode by following the
instructions provided by the
controller manufacturer.
One press one flash LED
Pressing INCLUDE_BUTTON three
times within 2 seconds will enter
inclusion mode.
Exclusion
Put your Z-Wave controller into
exclusion mode by following the
instructions provided by the
One press one flash LED
Pressing INCLUDE_BUTTON three
times within 2 seconds will enter
exclusion mode.
Node ID has been excluded.
LED 0.5s On, 0.5s Off
(Enter auto inclusion)
Reset
Pressing INCLUDE_BUTTON three
times within 2 seconds will enter
inclusion mode.
Use this procedure only in the
event that the primary controller is
lost or otherwise inoperable.
Within 1 second, press On/Off
button again for 5 seconds.
IDs are excluded.
LED 0.5s On, 0.5s Off