1. Overview
AirLive SA-102 User Manual
18
1.6.5.9. RF off command mode
Whenever a switch off command, BASIC_SET
、
BINARY_SWITCH_SET
、
SWITCH_ALL_OFF, is received, it could be interpreted as 4 kinds of commands.
1. Switch Off
:
It switches to OFF state. The default setting is Switch Off.
2. Ignore
:
The switch off command will be ignored.
3. Switch Toggle
:
It switches to the inverse of current state.
4. Switch On
:
It switches to ON state.
1.6.5.10. Existence of Endpoint3
Multi-Channel Command is a good way to control relay1 and relay2 of SA-102 individually.
The endpoint3 of SA-102 is related to both relay1 and relay2. In some condition it becomes
redundant in Multi-Channel Command Class. When the Existence of Endpoint3 is set as 2,
the endpoint3 will be disabled. The default value is 1.
Endpoint1 and Endpoint2 are fixed, only Endpoint3 is dynamic.
1.6.6. Protection Command Classes
SA-102 supports Protection Command Class version 2, it can protect the switch against
unintentionally control by e.g. a child. And it can also protect the switch from being turned
off by setting it in “No RF Control” state.
After being set to “Protection by sequence” state, any intentional pressing of On/Off button
or S2/S2 should be hold longer than 1 second, or the switch state will not change. However,
the operation of learn function does not change, because learning will not be protected.
1.6.7. Firmware update over the air (OTA)
SA-102 is based on 500 series SoC and supports Firmware Update Command Class, it can
receives the updated firmware image sent by controller via the Z-wave RF media. It is a
helpful and convenient way to improve some function if needed.
1.6.8. Command Classes
The Switch supports Command Classes including…
*
COMMAND_CLASS_ZWAVEPLUS_INFO
*
COMMAND_CLASS_VERSION_V2
*
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
*
COMMAND_CLASS_DEVICE_RESET_LOCALLY
*
COMMAND_CLASS_ASSOCIATION_V2
*
COMMAND_CLASS_ASSOCIATION_GRP_INFO
*
COMMAND_CLASS_POWERLEVEL
*
COMMAND_CLASS_SWITCH_BINARY
*
COMMAND_CLASS_BASIC
*
COMMAND_CLASS_SWITCH_ALL
*
COMMAND_CLASS_ALARM
*
COMMAND_CLASS_SCENE_ACTIVATION